Search arXivSearch

arXiv · 2408.11070

Nonlinear scintillation effects in the intrinsic luminescence from Sc$_{1.318}$Y$_{0.655}$Si$_{1.013}$O$_{4.987}$ crystal excited by electrons and gamma-quanta

Abstract

The spectral and kinetic properties of intrinsic luminescence from (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ crystal are studied. The emission is excited by electrons and gamma-quanta. The composition (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ is the congruent one for Sc$_2$SiO$_5$-Y$_2$SiO$_5$ solid solutions. It is found, that the crystal emits fairly bright intrinsic cathodololuminescence (CL) and radioluminescence (RL) at room temperature. In particular, the light yield of scintillation excited by -quanta with the energies of 661.7 keV is of 12000 photons/MeV. An increase in the beam flux by $\sim$20 times leads to the shift in the maximum CL energy spectral density from 315 to 340 nm and to the decrease in the CL decay time at 415 nm from 1377 +/- 3 ns to 1165 +/- 1 ns. Simultaneously, the decay time of RL excited by a photoelectron with the energy of 644.7 keV is of 1310 +/- 10 ns while a Compton electron with the energy of 477 keV excites RL with the decay time of 1050 +/- 10 ns. Also, we observed differences in the CL yield dependencies on the volume-averaged density of electronic excitations (EEs) at different wavelengths. An explanation of the results is given considering the nonlinear scintillation phenomena induced by an interaction between EEs. It is based on a conception that an increase in EE volume density leads to an increase in EEs nonradiative quenching due to these interactions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. V. Belov, V. A. Kozlov, N. V. Pestovskii, S. Yu. Savinov, V. S. Tskhay, V. I. Vlasov, A. I. Zagumennyi, Yu. D. Zavartsev, M. V. Zavertyaev. 2024-08-17. Nonlinear scintillation effects in the intrinsic luminescence from Sc$_{1.318}$Y$_{0.655}$Si$_{1.013}$O$_{4.987}$ crystal excited by electrons and gamma-quanta. https://arxiv.org/abs/2408.11070

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det