Search arXivSearch

arXiv · 2411.12833

Efficient Medicinal Image Transmission and Resolution Enhancement via GAN

Abstract

While X-ray imaging is indispensable in medical diagnostics, it inherently carries with it those noises and limitations on resolution that mask the details necessary for diagnosis. B/W X-ray images require a careful balance between noise suppression and high-detail preservation to ensure clarity in soft-tissue structures and bone edges. While traditional methods, such as CNNs and early super-resolution models like ESRGAN, have enhanced image resolution, they often perform poorly regarding high-frequency detail preservation and noise control for B/W imaging. We are going to present one efficient approach that improves the quality of an image with the optimization of network transmission in the following paper. The pre-processing of X-ray images into low-resolution files by Real-ESRGAN, a version of ESRGAN elucidated and improved, helps reduce the server load and transmission bandwidth. Lower-resolution images are upscaled at the receiving end using Real-ESRGAN, fine-tuned for real-world image degradation. The model integrates Residual-in-Residual Dense Blocks with perceptual and adversarial loss functions for high-quality upscaled images with low noise. We further fine-tune Real-ESRGAN by adapting it to the specific B/W noise and contrast characteristics. This suppresses noise artifacts without compromising detail. The comparative evaluation conducted shows that our approach achieves superior noise reduction and detail clarity compared to state-of-the-art CNN-based and ESRGAN models, apart from reducing network bandwidth requirements. These benefits are confirmed both by quantitative metrics, including Peak Signal-to-Noise Ratio and Structural Similarity Index, and by qualitative assessments, which indicate the potential of Real-ESRGAN for diagnostic-quality X-ray imaging and for efficient medical data transmission.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rishabh Kumar Sharma, Mukund Sharma, Pushkar Sharma, Jeetashree Aparjeeta. 2024-11-19. Efficient Medicinal Image Transmission and Resolution Enhancement via GAN. https://arxiv.org/abs/2411.12833

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV