Search arXivSearch

arXiv · 2503.10939

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Abstract

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory's Second Target Station (STS). Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence, and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. Additionally, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need of truly curved guides. To enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer $m$-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and $^3$He spin filters over the default polarized wavelength band of 1.2-5.5~Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average $P^2T$ of approximately 35\%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yaohua Liu, Peter Torres. 2025-03-13. Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option. https://doi.org/10.1063/5.0259079

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det