Search arXivSearch

arXiv · 2506.16210

From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction

Abstract

In motion-robust magnetic resonance imaging (MRI), slice-to-volume reconstruction is critical for recovering anatomically consistent 3D brain volumes from 2D slices, especially under accelerated acquisitions or patient motion. However, this task remains challenging due to hierarchical structural disruptions. It includes local detail loss from k-space undersampling, global structural aliasing caused by motion, and volumetric anisotropy. Therefore, we propose a progressive refinement implicit neural representation (PR-INR) framework. Our PR-INR unifies motion correction, structural refinement, and volumetric synthesis within a geometry-aware coordinate space. Specifically, a motion-aware diffusion module is first employed to generate coarse volumetric reconstructions that suppress motion artifacts and preserve global anatomical structures. Then, we introduce an implicit detail restoration module that performs residual refinement by aligning spatial coordinates with visual features. It corrects local structures and enhances boundary precision. Further, a voxel continuous-aware representation module represents the image as a continuous function over 3D coordinates. It enables accurate inter-slice completion and high-frequency detail recovery. We evaluate PR-INR on five public MRI datasets under various motion conditions (3% and 5% displacement), undersampling rates (4x and 8x) and slice resolutions (scale = 5). Experimental results demonstrate that PR-INR outperforms state-of-the-art methods in both quantitative reconstruction metrics and visual quality. It further shows generalization and robustness across diverse unseen domains.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhenxuan Zhang, Lipei Zhang, Yanqi Cheng, Zi Wang, Fanwen Wang, Haosen Zhang, Yue Yang, Yinzhe Wu, Jiahao Huang, Angelica I Aviles-Rivero, Zhifan Gao, Guang Yang, Peter J. Lally. 2026-03-23. From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction. https://arxiv.org/abs/2506.16210

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV