Search arXivSearch

arXiv · 2507.19199

Enhancing Diabetic Retinopathy Classification Accuracy through Dual Attention Mechanism in Deep Learning

Abstract

Automatic classification of Diabetic Retinopathy (DR) can assist ophthalmologists in devising personalized treatment plans, making it a critical component of clinical practice. However, imbalanced data distribution in the dataset becomes a bottleneck in the generalization of deep learning models trained for DR classification. In this work, we combine global attention block (GAB) and category attention block (CAB) into the deep learning model, thus effectively overcoming the imbalanced data distribution problem in DR classification. Our proposed approach is based on an attention mechanism-based deep learning model that employs three pre-trained networks, namely, MobileNetV3-small, Efficientnet-b0, and DenseNet-169 as the backbone architecture. We evaluate the proposed method on two publicly available datasets of retinal fundoscopy images for DR. Experimental results show that on the APTOS dataset, the DenseNet-169 yielded 83.20% mean accuracy, followed by the MobileNetV3-small and EfficientNet-b0, which yielded 82% and 80% accuracies, respectively. On the EYEPACS dataset, the EfficientNet-b0 yielded a mean accuracy of 80%, while the DenseNet-169 and MobileNetV3-small yielded 75.43% and 76.68% accuracies, respectively. In addition, we also compute the F1-score of 82.0%, precision of 82.1%, sensitivity of 83.0%, specificity of 95.5%, and a kappa score of 88.2% for the experiments. Moreover, in our work, the MobileNetV3-small has 1.6 million parameters on the APTOS dataset and 0.90 million parameters on the EYEPACS dataset, which is comparatively less than other methods. The proposed approach achieves competitive performance that is at par with recently reported works on DR classification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Abdul Hannan, Zahid Mahmood, Rizwan Qureshi, Hazrat Ali. 2025-07-25. Enhancing Diabetic Retinopathy Classification Accuracy through Dual Attention Mechanism in Deep Learning. https://arxiv.org/abs/2507.19199

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

KELP: K-space-conditioned Estimation of Learned Sampling Patterns for Scan-Adaptive Multi-Coil MRI

Deep learning techniques have gained considerable attention for accelerating MRI acquisition while maintaining image quality. In this work, we present a convolutional neural network (CNN)-based framework for predicting scan-adaptive undersampling patterns directly from low-frequency multi-coil $k$-space data. Unlike approaches that optimize sampling patterns during training or rely on nearest-neighbor search at inference, our method is trained using precomputed scan-adaptive optimized masks as supervised labels and predicts a scan-specific sampling pattern in a single forward pass. The training procedure alternates between optimizing the sampling network and a reconstruction network, allowing the learned masks to adapt to reconstruction performance. Experiments on the fastMRI multi-coil knee dataset demonstrate competitive reconstruction quality compared with existing population- and scan-adaptive sampling approaches at $4\times$ and $8\times$ acceleration factors. In addition, the proposed method enables efficient scan-specific mask prediction with inference cost independent of the training dictionary size.

eess.IV

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV