Search arXiv⌕ Search

arXiv · 2508.07846

Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment

Abstract

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. Abe, H. Alarakia-Charles, I. Alekseev, C. Alt, T. Arai, T. Arihara, S. Arimoto, A. M. Artikov, Y. Awataguchi, N. Babu, V. Baranov, G. Barr, D. Barrow, L. Bartoszek, L. Bernardi, L. Berns, S. Bhattacharjee, A. V. Boikov, A. Blanchet, A. Blondel, A. Bonnemaison, S. Bordoni, M. H. Bui, T. H. Bui, F. Cadoux, S. Cap, A. Cauchois, J. Chakrani, P. S. Chong, A. Chvirova, P. Collard, M. Danilov, C. Davis, V. Davouloury, Yu. I. Davydov, A. Dergacheva, C. Domangue, D. Douqa, T. A. Doyle, O. Drapier, A. Eguchi, J. Elias, G. Erofeev, Y. Favre, D. Fedorova, S. Fedotov, D. Ferlewicz, Y. Fujii, R. Fujita, Y. Furui, F. Gastaldi, A. Gendotti, A. Germer, L. Giannessi, C. Giganti, V. Glagolev, R. Guillaumat, G. Ha, N. C. Hastings, I. Heitkamp, J. Hu, C. Husi, A. K. Ichikawa, T. H. Ishida, A. Izmaylov, K. Iwamoto, M. Jakkapu, C. Jesús-Valls, J. Y. Ji, P. Jonsson, C. K. Jung, H. Kakuno, V. S. Kasturi, M. Kawaue, P. T. Keener, M. Khabibullin, N. V. Khomutov, A. Khotjantsev, T. Kikawa, H. Kikutani, N. V. Kirichkov, A. Klustová, H. Kobayashi, T. Kobayashi, L. Koch, S. Kodama, A. O. Kolesnikov, M. Kolupanova, A. Korzenev, T. Koto, Y. Kudenko, S. Kuribayashi, T. Kutter, M. Lachat, K. Lachner, M. Lamers James, D. Last, N. Latham, M. Lawe, T. A. Le. 2025-09-19. Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment. https://doi.org/10.1088/1748-0221%2F20%2F10%2Fp10030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Disentangling mixed neutron fields: multi-source identification from few detected events

Identifying neutron-emitting materials is central to nuclear nonproliferation, safeguards, nuclear forensics, and emergency response, yet remains difficult when several sources contribute simultaneously: relevant fission, $(α,\text{n})$, and fusion sources emit broad, strongly overlapping energy distributions, and the associated spectral inversion is severely ill-conditioned. Here we demonstrate quantitative identification of mixed neutron fields directly from scatter-based (recoil) spectroscopy measurements, together with simultaneous estimation of the emission rate of each contributing source and a rigorous statistical confidence level for every candidate source combination. Using a compact $21.6\,\mathrm{cm}^3$ organic-glass scintillator spectrometer, we correctly identify Cf-252, a deuterium--deuterium (DD) neutron generator, and their mixture with decisive statistical support ($>\!4σ$), and further resolve a weak deuterium--tritium contaminant in the nominal DD generator field. High-fidelity Monte Carlo simulations spanning exhaustive single-, two-, and three-source mixtures show that identification requires remarkably little information: between $\mathcal{O}(10^1)$ and $\mathcal{O}(10^6)$ detected recoil events, set primarily by spectral similarity, mixture complexity, and emission-rate imbalance. For the compact spectrometer used here, this corresponds to acquisition times as short as a few minutes. These results substantially extend the operational reach of simple single-volume neutron spectrometers, enabling rapid, quantitative, and confidence-calibrated attribution of complex neutron fields in field-deployable instruments.

physics.ins-det↗

Femtoscopy Measurement with S$π$RIT TPC in Radioactive BeamHeavy-ion Collisions

Femtoscopy is a powerful tool for exploring the dynamic emitting structure in heavy-ion collisions, while radioactive beam heavy-ion collisions enable the investigation of nuclear matter under extreme isospin conditions. Here, we successfully perform femtoscopy measurements using the S$π$RIT Time Projection Chamber (TPC). A dedicated correction scheme for track merging and splitting is proposed, which is well applicable to rectangular TPCs housed inside dipole magnets and effectively improves the reconstructed correlation functions at small relative momenta. Focusing on the proton-proton (p-p) correlation function in the 270 MeV/u $^{132}\text{Sn}+^{124}\text{Sn}$ system, we successfully apply the track merging and splitting correction; additionally, the TPC angular acceptance exhibits a negligible impact on the correlation function. A systematic uncertainty quantification framework is established. The experimental results of the p-p correlation function confirm the feasibility of the S$π$RIT TPC for femtoscopy measurements and provide technical support for high-precision femtoscopy studies using rectangular TPCs in radioactive beam heavy-ion collisions.

physics.ins-det↗

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det↗