Supersonic gas curtain based real-time ionization profile monitor for hadron therapy

Abstract

Accurate control and monitoring of the beam is essential for precise dose delivery to tumor tissues during radiotherapy. Real-time monitoring of ion beam profiles and positions improves beam control, patient safety, and treatment reliability by providing immediate feedback. This becomes even more critical in FLASH therapy, where the short corrective window during high-dose delivery demands precise beam control. Existing devices are often limited to in vitro calibration or focus on monitoring a single parameter during treatment. This study aims to develop a device that can simultaneously monitor beam position, profile, current, and energy in real-time, without perturbing the beam, using a supersonic gas curtain system. A supersonic gas curtain beam profile monitor was developed at the Cockcroft Institute to assess its performance and suitability for applications in hadron-beam therapy. The system was integrated with one of the beamlines of the Pelletron accelerator at the Dalton Cumbrian Facility, UK and 2D profile measurements of carbon beams were conducted. The monitor successfully measured the beam profiles within 100ms to 1s across various beam currents (1 - 100 nA), energies (12 - 24 MeV), and charge states (2-5) of carbon. Recorded data was used to estimate detector performance by introducing a parameter called detection limit to quantify sensitivity of the monitor, identifying the threshold number of ions required for detection onset. A method to quantify sensitivity under different beam conditions is then discussed in detail, illustrated with an example case of FLASH beam parameters. This proof-of-concept study demonstrates the performance of the gas curtain-based ionization profile monitor for 2D transverse beam profile measurement of carbon ions. The sensitivity is quantified and evaluated against an example case for FLASH conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Narender Kumar, Milaan Patel, William Butcher, Hao Zhang, Oliver Stringer, Joseph Wolfenden, Carsten P Welsch. 2025-09-18. Supersonic gas curtain based real-time ionization profile monitor for hadron therapy. https://arxiv.org/abs/2509.14892

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Approximate solution of an adapted Bethe transport equation for electron scattering in foils

A new semi-analytical model for electron scattering in foils is presented valid for thin foils and electron-beam kinetic energies up to roughly $100$ keV and from 20 keV at a dimensionless foil thickness of $20$, and higher energies for thinner foils. To perform calculations, an approximate solution is constructed by Hankel transforms of an adapted Bethe transport equation for electron scattering. The Wentzel differential cross section is used in the Bethe transport Eq. and resulting integrals are solved analytically or approximated. These approximate solutions of the transport Eq.'s were compared to the Goudsmit-Saunderson solutions in gold, for thin samples with dimensionless thicknesses $λ=5,10,20$. We also compare to the Kawrakow \cite{Kawr} model, which uses the small angle approximation. We show that in the regime of $20$ to $100$ keV beam energies, our model performs better than Kawrakow's model and this is opposite above about 100 keV. Exactly, some angularly distributed beams and the influence of energy loss of the beam can be simulated with our model.

physics.acc-ph

Reconstruction of Beam Transverse Parameters in the Fermilab Side-Coupled Linac Using a Normalized Coordinate Framework

Quadrupole scans are a commonly used tool for beam second moment reconstruction. Limitations in the strength of the magnets and layout of the beamline elements frequently preclude simple quadrupole-drift-detector scans from collecting sufficient data for reconstruction. Using a normalized coordinate framework, we characterize the prerequisites for a robust simple quadrupole scan and expand these prerequisites to reconstruction from more complex optics. The beam second moments are investigated at two locations in the Fermilab Side-Coupled Linac under simple and complex optics, using this framework to maximize information gained from wire scanner profile measurements.

physics.acc-ph

Impedance of multilayer cylindrical structures with a material-filled beam region

Beam-coupling impedances in material media are relevant for ionization-cooling channels of a future muon collider, where the beam propagates in matter rather than vacuum. We extend the cylindrical field-matching formalism for multilayer structures to the case of a material-filled beam region surrounded by external layers with arbitrary electromagnetic properties. Relative to the vacuum formulation, the usual factor $1/γ^2$ is replaced by the material-dependent factor $F=1/\varepsilon_1-μ_1β^2$, and the radial propagation constant is modified accordingly. Analytical expressions are obtained for the monopolar longitudinal and dipolar transverse impedances, with the surrounding structure encoded through reflection coefficients determined by field matching. The formalism reduces to the known vacuum and perfectly conducting limits in the appropriate cases. Representative calculations are presented for absorber-relevant configurations, illustrating the dependence on the material properties of both the beam region and the surrounding layers. In particular, a finite beam-region conductivity can generate a real impedance component and reverse the sign of the imaginary space-charge impedance, while sufficiently high permittivity can give rise to resonant structures associated with oscillatory radial fields. The effect of finite-conductivity surroundings is also examined, showing the approach towards the perfectly conducting limit as the external conductivity is increased. The applicability of the infinite-length approximation is also discussed by comparison with finite-length mode-matching results.

physics.acc-ph