High frame rate RIXS spectroscopy using a JUNGFRAU detector with an iLGAD sensor

Abstract

Resonant inelastic X-ray scattering (RIXS) is a powerful photon-in, photon-out spectroscopy technique for probing electronic, magnetic, and lattice excitations in matter. Time-resolved RIXS extends this capability through a stroboscopic optical pump-probe scheme to characterize the time evolution of the photoexcitation and subsequent relaxation dynamics of a sample. This technique is, however, extremely photon-hungry, requiring high-repetition-rate and intense X-ray facilities. The Heisenberg RIXS (hRIXS) spectrometer at the Spectroscopy and Coherent Scattering (SCS) instrument of the European X-ray Free-Electron Laser (EuXFEL) is designed to exploit high-repetition-rates, while maintaining optimal time and energy resolution. In this work, we demonstrate the successful deployment of a JUNGFRAU detector equipped with an inverse Low Gain Avalanche Diode (iLGAD) sensor for time-resolved RIXS studies in the soft X-ray range, using the hRIXS spectrometer. A spatial resolution of $19.71 \pm 0.7~μ\mathrm{m}$ and a resolving power exceeding 10,000 were achieved at an unprecedented frame rate of 47 kHz. Intra-train resolved data measured with a high FEL peak fluence of $1.8~\mathrm{mJ/cm^{2}}$ for a 928.5 eV ph photon energy and 1.1 MHz repetition rate from cupric oxide (CuO) revealed a decrease in the emitted signal by ~10% over a time interval of $340~μ\mathrm{s}$, indicating FEL-induced effects that require monitoring when conducting high-repetition-rate experiments. These results establish the JUNGFRAU-iLGAD as a promising detector to harvest the full potential of the hRIXS spectrometer, and validate its suitability for soft X-ray applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nuno Duarte, Loïc Le Guyader, Viktoria Hinger, Marco Ramilli, Justine Schlappa, Robert Carley, Maria Carulla, Yi-Ping Chang, Devesh Chopra, Natalia Gerasimova, Michael Grimes, Aldo Mozzanica, Sergii Parchenko, Le Phuong Hoang, Urs Staub, Jiaguo Zhang, Anna Bergamaschi, Andreas Scherz, Bernd Schmitt, Monica Turcato. 2025-11-15. High frame rate RIXS spectroscopy using a JUNGFRAU detector with an iLGAD sensor. https://arxiv.org/abs/2511.12314

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det