Search arXivSearch

arXiv · 2512.22176

Field strength-dependent performance variability in deep learning-based analysis of magnetic resonance imaging

Abstract

This study quantitatively evaluates the impact of MRI scanner magnetic field strength on the performance and generalizability of deep learning-based segmentation algorithms. Three publicly available MRI datasets (breast tumor, pancreas, and cervical spine) were stratified by scanner field strength (1.5T vs. 3.0T). For each segmentation task, three nnU-Net-based models were developed: A model trained on 1.5T data only (m-1.5T), a model trained on 3.0T data only (m-3.0T), and a model trained on pooled 1.5T and 3.0T data (m-combined). Each model was evaluated on both 1.5T and 3.0T validation sets. Field-strength-dependent performance differences were investigated via Uniform Manifold Approximation and Projection (UMAP)-based clustering and radiomic analysis, including 23 first-order and texture features. For breast tumor segmentation, m-3.0T (DSC: 0.494 [1.5T] and 0.433 [3.0T]) significantly outperformed m-1.5T (DSC: 0.411 [1.5T] and 0.289 [3.0T]) and m-combined (DSC: 0.373 [1.5T] and 0.268[3.0T]) on both validation sets (p<0.0001). Pancreas segmentation showed similar trends: m-3.0T achieved the highest DSC (0.774 [1.5T], 0.840 [3.0T]), while m-1.5T underperformed significantly (p<0.0001). For cervical spine, models performed optimally on same-field validation sets with minimal cross-field performance degradation (DSC>0.92 for all comparisons). Radiomic analysis revealed moderate field-strength-dependent clustering in soft tissues (silhouette scores 0.23-0.29) but minimal separation in osseous structures (0.12). These results indicate that magnetic field strength in the training data substantially influences the performance of deep learning-based segmentation models, particularly for soft-tissue structures (e.g., small lesions). This warrants consideration of magnetic field strength as a confounding factor in studies evaluating AI performance on MRI.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Muhammad Ibtsaam Qadir, Duane Schonlau, Ulrike Dydak, Fiona R. Kolbinger. 2025-12-18. Field strength-dependent performance variability in deep learning-based analysis of magnetic resonance imaging. https://arxiv.org/abs/2512.22176

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV

Recasting the Destroy Step of Large Neighborhood Search as Dense Segmentation

Large neighborhood search improves an incumbent by releasing selected variables and repairing the resulting subproblem under a time limit. FOVEA casts variable selection as dense semantic segmentation on a fixed $128\times128$ canvas. A small U-Net reads twelve semantic channels and predicts cell scores, which are decoded into a variable set subject to a fixed variable budget. Family-specific layouts connect the search state to the canvas, while one set of network weights serves four problem families. The FP32 network input occupies $786$\,kB across instance sizes. Our analysis bounds constraint coupling for spatially coherent regions, gives a rank certificate for rounds with zero possible improvement, and bounds the coupling advantage attainable on an expander family. On the tested families and hardware, FOVEA trails the strongest graph encoder at $10^{4}$ variables and overtakes it near $1.5\times10^{4}$; the cost model provides an approximate crossover estimate. At larger sizes, where the graph-encoder baselines exceed device memory, FOVEA reduces the primal integral by $12$ to $16\%$ relative to the best runnable baselines. On the expander family, FOVEA performs comparably to random selection, with a coupling advantage close to one.

eess.IV