Search arXivSearch

arXiv · 2604.00070

Brain MR Image Synthesis with 3D Multi-Contrast Self-Attention GAN

Abstract

Complete and high-quality multi-modal Magnetic Resonance Imaging (MRI) is essential for accurate neuro-oncological assessment, as each contrast provides complementary anatomical and pathological information. However, acquiring all modalities (e.g., T1c, T1n, T2w, T2f) for every patient is often impractical due to prolonged scan times, cost, and patient discomfort, potentially limiting comprehensive tumour evaluation. We propose 3D-MC-SAGAN (3D Multi-Contrast Self-Attention Generative Adversarial Network), a unified 3D multi-contrast synthesis framework that generates high-fidelity missing modalities from a single T2w input while explicitly preserving tumour characteristics. The model employs a multi-scale 3D encoder--decoder generator with residual connections and a novel Memory-Bounded Hybrid Attention (MBHA) block to capture long-range dependencies efficiently, and is trained with a WGAN-GP critic and an auxiliary domain classification head to produce T2f, T1n, and T1c volumes within a unified network. To ensure anatomical and pathological fidelity, we incorporate a frozen 3D U-Net-based segmentation network that enforces a tumour-consistency constraint during training. A composite objective combining adversarial, reconstruction, perceptual, structural similarity, contrast-classification, and segmentation-guided losses further promotes both global realism and tumour-preserving structure. Extensive experiments on 3D brain MRI datasets demonstrate that 3D-MC-SAGAN achieves state-of-the-art quantitative performance and produces visually coherent, anatomically plausible contrasts with improved distributional realism. Importantly, the proposed method maintains tumour segmentation accuracy comparable to that achieved using fully acquired multi-modal inputs, highlighting its potential to reduce acquisition burden while preserving clinically meaningful information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zaid A. Abod, Furqan Aziz. 2026-04-30. Brain MR Image Synthesis with 3D Multi-Contrast Self-Attention GAN. https://arxiv.org/abs/2604.00070

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV