Search arXivSearch

arXiv · 2604.12711

Automated Design of Tubular Origami with Anisotropic Stiffness

Abstract

Thin sheets can be assembled into tubular origami structures that combine deployability with pronounced anisotropic stiffness, enabling applications ranging from robotics to deployable systems. However, most existing tubular origami designs remain limited to degree-four vertex topologies and are characterized primarily in axial and radial loading modes, without a full assessment of anisotropic stiffness. Here, we present an automated design framework for tubular origami that jointly explores local vertex topology through generalized degree-$n$ vertices and global tube topology through the polygonal cross-section, for the systematic design and optimization of anisotropic stiffness. Using a calibrated bar-and-hinge model together with experimental validation, we quantify large-deformation stiffness responses in axial translation, in-plane translation, torsion about the tube axis, and rotation about in-plane axes, thereby characterizing the anisotropic stiffness of the tube across its compliant and constrained deformation modes. The resulting design-space exploration showed that the polygonal cross-sectional topology is the primary factor governing the anisotropic stiffness. We further show that increasing the local vertex degree can improve global structural performance, particularly for tubes with a small number of cross-sectional vertices, demonstrating that higher local kinematic freedom does not necessarily compromise stiffness at the structural scale. Compared with a benchmark design, the optimized architectures achieve more than 50 times higher constrained rotational stiffness. Together, these results highlight higher-degree vertices and polygonal cross-sectional topology as powerful design variables for tailoring anisotropic stiffness in tubular origami.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mingkai Zhang, Davood Farhadi. 2026-04-14. Automated Design of Tubular Origami with Anisotropic Stiffness. https://arxiv.org/abs/2604.12711

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph