Search arXivSearch

arXiv · 2605.26726

Measuring Prediction Uncertainty in Neural Cellular Automata

Abstract

Neural cellular automata (NCA) provide a lightweight alternative to encoder-decoder segmentation networks. However, it can be difficult to decide when a prediction should be trusted. Here, we study uncertainty estimation for NCA-based medical image segmentation without modifying the underlying architecture or retraining the model. Our approach is motivated by viewing the NCA as a dynamical system where convergent attractors correspond to confident predictions. Concretely, we propose resilience, a simple measure that leverages the intrinsic iterative structure of NCAs by probing the stability of the final prediction under small perturbations of the automaton state. Predictions that return to the same solution are deemed confident, while those that change substantially are flagged as uncertain. We evaluate uncertainty by its ability to predict segmentation quality using selective prediction metrics ($Δ$Dice@90 and AURC) and ranking metrics (AUROC and AUPRC). Across multiple medical segmentation benchmarks, resilience identifies failure cases more reliably than baselines, improving trust and safety in NCA-based models.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ario Sadafi, Michael Deutges, Nassir Navab, Carsten Marr. 2026-05-26. Measuring Prediction Uncertainty in Neural Cellular Automata. https://arxiv.org/abs/2605.26726

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Dipole-lets: a new multiscale decomposition for MR phase and quantitative susceptibility mapping

Nondipolar phase contributions can generate severe streaking artifacts during quantitative susceptibility mapping (QSM) inversion. We propose Dipole-lets, a dipole-adapted multiscale decomposition designed to identify phase components associated with streaking artifacts before and during susceptibility inversion. Dipole- lets combine an undecimated radial decomposition with an angular partition based on proximity to the magic cone. The resulting coefficients emphasize phase components near the magic cone, where nondipolar contributions may become relatively prominent. This information was incorporated into QSM reconstruction through a data- driven fidelity weight and a Dipole-let-based regularizer that models an additional nondipolar phase component. The methods were evaluated using modified simulated QSM data and an in vivo dataset. The data-driven weighting reduced streaking artifacts while preserving anatomical detail and improved quantitative reconstruction metrics compared with magnitude-weighted TV. The Dipole-let regularizer achieved streaking suppression comparable to L1-QSM and lower reconstruction error in the modified simulated dataset. In vivo experiments further demonstrated the applicability of the proposed approach to data with strong susceptibility-induced phase perturbations. Dipole-lets provide a multiscale representation for characterizing phase components associated with streaking artifacts and incorporating this information into QSM reconstruction, reducing streaking while preserving relevant susceptibility structures, and providing a flexible basis for future QSM reconstruction methods.

eess.IV

MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging

In the field of medical imaging, AI-assisted techniques such as object detection, segmentation, and classification are widely employed to alleviate the workload of physicians and doctors. However, single-task models are predominantly used, overlooking the shared information across tasks. This oversight leads to inefficiencies in real-life applications. In this work, we propose MTMed3D, a novel end-to-end Multi-task Transformer-based model to address the limitations of single-task models by jointly performing 3D detection, segmentation, and classification in medical imaging. Our model uses a Transformer as the shared encoder to generate multi-scale features, followed by CNN-based task-specific decoders. The proposed framework was evaluated on the BraTS 2018 and 2019 datasets, achieving promising results across all three tasks, especially in detection, where our method achieves better results than prior works. Additionally, we compare our multi-task model with equivalent single-task variants trained separately. Our multi-task model significantly reduces computational costs and achieves faster inference speed while maintaining comparable performance to the single-task models, highlighting its efficiency advantage. To the best of our knowledge, this is the first work to leverage Transformers for multi-task learning that simultaneously covers detection, segmentation, and classification tasks in 3D medical imaging, presenting its potential to enhance diagnostic processes. The code is available at https://github.com/fanlimua/MTMed3D.git.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV