Evaluation of EEG Foundation Models for Event-Based Burst-Suppression Detection in ICU

Abstract

Burst suppression (BS) is a clinically relevant electroencephalographic (EEG) pattern used to monitor sedation depth and brain activity in critically ill patients, particularly during induced coma in Intensive Care Units (ICUs). Automatic burst detection remains challenging because BS patterns vary substantially between patients and annotated datasets are scarce. Recently, EEG Foundation Models (FMs) have shown promise across several downstream EEG applications, but their usefulness for BS detection remains unexplored. We present the first study to evaluate EEG FMs for burst detection in reduced-montage ICU EEG without patient-specific calibration. We compare REVE-base, LUNA-large and LuMamba-Tiny with an adaptive thresholding baseline and a task-specific EEGNet baseline. Additionally, we complement conventional EEG window-based classification with event-based burst detection evaluation. This helps assessing clinically whether burst episodes are correctly detected, reducing the impact of expected annotation variability. The best model, REVE-base, achieved the highest event-based F1-score ($0.868 \pm 0.167$) and reduced burst-per-minute error by 52.1% and 36.2% compared to EEGNet and adaptive thresholding respectively, supporting FMs for scalable EEG monitoring in ICU. Ablation experiments showed that full fine-tuning was the most effective adaptation strategy with respect to frozen-backbone training, two-step fine-tuning, and LoRA-based adaptation, improving event-based F1-score over frozen-backbone training by up to $+0.102$ for LUNA-large. With reduced labeled datasets, pretrained REVE-base outperformed random initialization by $+0.723$ event-based F1 points at 25% of the cohort, demonstrating the benefit of pretraining FM representations when adapted to burst detection with limited labeled data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elisa Vasta, Thorir Mar Ingolfsson, Andrea Cossettini, Luca Benini, Tilman Beck, Emanuela Keller, Una Pale. 2026-06-18. Evaluation of EEG Foundation Models for Event-Based Burst-Suppression Detection in ICU. https://arxiv.org/abs/2606.20074

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circulant ADMM-Net for Fast High-resolution DoA Estimation

This paper introduces CADMM-Net and CHADMM-Net, two deep neural networks for direction of arrival estimation within the least-absolute shrinkage and selection operator (LASSO) framework. These two networks are based on a structured deep unfolding of the alternating direction method of multipliers (ADMM) algorithm through the use of circulant as well as Hermitian-circulant matrices. Along with a computational complexity of $\mathcal{O}(N\log(N))$ per layer for the inference, where $N$ is the length of the dictionary $\mathbf{A}$, they additionally exhibit a memory footprint of $N$ and approximately half of $N$ for CADMMNet and CHADMM-Net, respectively, compared with $N^{2}$ for ADMM-Net. Furthermore, these structured networks exhibit a competitive performance against ADMM-Net, LISTA, TLISTA, and THLISTA with respect to the detection rate, the angular root-mean square error, and the normalized mean squared error.

eess.SP

BASIIS: Bistatic Angular Sampling and Interpolation for ISAC Setups

Integrated Sensing and Communications (ISAC) is a defining feature of 6G, extending cellular networks with radar-like sensing at limited additional overhead. In bistatic deployments, sensing requires coordinating the transmitter (TX) and receiver (RX) arrays to scan the Cartesian product of angle of departure and arrival, resulting in a four-dimensional sampling problem in the angular domain. This work establishes a complete angular sampling framework for bistatic ISAC, extending the DFT-based optimal-sampling methodology to the full azimuth and elevation domains of both arrays. We show that the bistatic geometry couples the TX and RX elevation angles, and represent this coupling through the ortho-baseline coarray, a virtual array that captures the joint elevation aperture of the array pair. From the coarray we derive a minimal sampling and interpolation scheme, near-lossless and realizable with any beamforming architecture. Monte Carlo simulations confirm the proposed minimal acquisition essentially equalizes the detection accuracy of dense oversampled imaging while acquiring 3 to 5 times fewer TX-RX direction pairs. This allows having bistatic operations with drastically reduced overhead on the radio resource usage of ISAC systems.

eess.SP

Centroid Angle Estimation of Multiple Scatterers Using Monopulse Radar with Frequency Diversity

The monopulse technique determines the angle of a target by comparing signals from two narrow beams, yielding a precise angular estimate with low complexity. However, it struggles to resolve multiple closely spaced scatterers within the same resolution cell. Existing methods for estimating multiple scatterer angles involve complex signal processing and system modifications. We propose an effective method to estimate the angular centroid of scatterers using the mode of monopulse angle estimates. A semi-analytic expression for the angle estimate distribution is derived, confirming that its mode aligns with the centroid. To enhance estimation accuracy, we employ frequency diversity to reduce sample correlation. Numerical results validate the advantages of the proposed method, demonstrating superior performance over conventional techniques with low complexity.

eess.SP