Large Language Model-Assisted Cleaning of Report-Derived Labels in a Large-Scale Chest CT Dataset

Abstract

Purpose: To evaluate whether large language model (LLM)-assisted label cleaning can identify label-report discordance in CT-RATE, a large-scale public chest CT dataset. Materials and Methods: After report-level deduplication, 24,446 unique radiology reports were identified. Twelve reports were excluded from the primary GPT-5.4 analysis because of Microsoft Azure AI Foundry content-safety filtering, leaving 24,434 reports and 439,812 label instances across 18 abnormality categories. GPT-5.4-derived binary labels were generated from report text using structured JSON output and compared with existing CT-RATE labels. Discordant instances were adjudicated by radiologists. In addition, 100 randomly sampled reports were manually annotated to compare CT-RATE labels, individual LLM-derived labels, and multi-LLM majority-vote labels against radiologist-annotated reference labels. Results: Overall agreement between GPT-5.4-derived and CT-RATE labels was 96.4%, with Cohen's kappa of 0.884. Lymphadenopathy showed the lowest agreement and kappa. In discordance review, radiologist adjudication supported GPT-5.4-derived labels in 72 of 97 (74.2%) general discordant instances and 91 of 99 (91.9%) targeted lymphadenopathy discordant instances. Against radiologist-annotated reference labels, multi-LLM majority-vote labels achieved the highest label-macro-averaged F1 score and Cohen's kappa. Conclusion: LLM-assisted label cleaning identified clinically meaningful label-report discordance in CT-RATE and may support scalable quality improvement of public imaging datasets. The cleaned dataset will be made publicly available to support future research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yosuke Yamagishi, Atsushi Takamatsu, Mototsugu Sato, Tomohiro Kikuchi, Shouhei Hanaoka, Takeharu Yoshikawa, Osamu Abe. 2026-06-21. Large Language Model-Assisted Cleaning of Report-Derived Labels in a Large-Scale Chest CT Dataset. https://arxiv.org/abs/2606.22382

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV