Search arXivSearch

arXiv · 2608.00058

Automated ECG Interval Measurement and Wave Delineation Using Fast Fourier Convolution ResNet

Abstract

Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts. We bridge this gap by evaluating a complete end-to-end pipeline on 10,646 clinical 12-lead ECGs and reporting the first large-scale interval measurement accuracy study with full statistical characterisation, including bias, 95% limits of agreement (Bland-Altman), bootstrap confidence intervals, and rhythm-stratified error analysis. The underlying delineation is performed by a Fast Fourier Convolution ResNet (FFCResNet), adapting local temporal convolutions with global spectral processing via FFT and augmented with register tokens for contextual feature learning. Three per-wave models (P, QRS, and T) are trained on six public databases with ECG-specific augmentation. On 10,646 ECGs, the system achieves a QT MAE of 17.5 ms [95% CI: 16.9-18.2], with a Bland-Altman bias of +8.5 ms (LoA: -68.5 to +85.5 ms); a QRS duration MAE of 14.8 ms [95% CI: 14.6-15.0], with a bias of +12.6 ms (LoA: -12.3 to +37.6 ms); and a ventricular rate MAE of 0.8 beats/min. All biases are statistically significant by the Wilcoxon signed-rank test (p < 0.001) but remain within or near published inter-observer variability bounds for sinus rhythms. Rhythm-stratified analysis reveals substantially higher QT errors for supraventricular tachycardias (SVT MAE: 75.0 ms; AVRT MAE: 85.3 ms) than for sinus bradycardia (SB MAE: 9.3 ms) and sinus rhythm (SR MAE: 8.9 ms), providing an honest characterisation of the deployment scope. Wave segmentation achieves internal Dice scores of 95.5%, 98.2%, and 96.1% for P, QRS, and T waves, respectively, and cross-database Dice scores of 78.1%, 85.5%, and 74.2%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari. 2026-08-04. Automated ECG Interval Measurement and Wave Delineation Using Fast Fourier Convolution ResNet. https://arxiv.org/abs/2608.00058

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP