Search arXivSearch

arXiv · 2608.08967

Automated generation of experimentally validated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications

Abstract

In battery manufacturing, the low-dew-point air conditioning of dry rooms is among the largest energy consumers, and a physics-based digital twin offers insight for operating-point optimization beyond the installed monitoring points. Building one and calibrating it to field data each demand distinct expertise, which limits industrial uptake. We present a framework that generates a dynamic digital twin of an HVAC system from a declarative topology specification, concise enough to draft from a natural-language plant description, compiled against a purpose-built physical component library with wiring, solver, and telemetry synthesized automatically. The models carry equipment-level physics: the desiccant wheel couples heat and mass transfer through an interchangeable sorption-isotherm component, so an undisclosed commercial sorbent is calibrated as an effective isotherm rather than asserted as a material. For experimental validation we built an industrial-grade, ten-component low-dew-point system whose commercial desiccant-wheel unit holds a chamber near -40 °C frost point, and operated it in both dehumidification and bypass regimes. Generation reached a runnable model fifteen times faster than expert manual construction, and a single parameter set, fitted only to three closed-loop humidity nodes, predicts the bypass regime within 0.1 °C, the reactivation-heater power within 5%, and measured input-step responses. Identifiability analysis shows why this is prediction, not fitting: ordinary operating points constrain only one parameter combination, and the deep-dry equilibrium level of the recirculating loop supplies the missing signal. The framework shortens the path from plant description to measurement-validated twin; its criteria-based calibration is a step toward twins calibrated, not only constructed, automatically.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Younghwan Joo, Jeonghoon Han, Sang Hyun Oh, Soosik Bang, Sung-il Kim. 2026-08-10. Automated generation of experimentally validated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications. https://arxiv.org/abs/2608.08967

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Failure-Aware Iterative Learning of State-Control Invariant Sets

In this paper, we address the problem of computing maximal state-control invariant sets for deterministic linear systems using failing trajectories. We introduce the concept of state-control invariance, which extends control invariance from the state space to the joint state-control space. The maximal state-control invariant (MSCI) set simultaneously encodes the maximal control invariant set (MCI) and, for each state in the MCI, the set of control inputs that preserve invariance. We prove that the state projection of the MSCI is the MCI and the state-dependent sections of the MSCI are the admissible invariance-preserving inputs. Building on this framework, we develop a Failure-Aware Iterative Learning (FAIL) algorithm for deterministic linear time-invariant systems with polytopic constraints. The algorithm iteratively updates a constraint set in the state-control space by learning predecessor halfspaces from one-step failing state-input pairs, without knowing the dynamics. For each failure, FAIL learns the violated halfspaces of the predecessor of the constraint set by a regression on failing trajectories. We prove that the learned constraint set converges monotonically to the MSCI. Numerical experiments on a double integrator system validate the proposed approach.

eess.SY

Consensus and Synchronization of Multi-agent Systems over Finite Fields - Graph Topologies

This paper presents cooperative protocols for multi-agent systems with agents having a finite state-space. Both scalar single-integrator consensus and general LTI system synchronization are considered. Systems having a finite state-space describe agents with minimal memory capacity processing only a finite alphabet. Such systems are remarkably resilient to communication noise. The crucial problem, however, is to construct the admissible communication topology, which is NP-hard. We address this by efficiently exploring the subsets of admissible graph matrices and propose two new algorithms to generate them. Simulations validate the proposed approach.

eess.SY

Extracting Exact Lie Derivatives Without Backpropagation: A Dual Compiler for Neural Control Barrier Functions

A safety filter based on a neural control barrier function (CBF) deployed in an embedded control loop evaluates, at each control cycle, the trained network and its Lie derivatives along the system vector fields, under the memory and worst-case execution time (WCET) constraints that safety-oriented coding standards impose. Reverse-mode automatic differentiation, by which training frameworks obtain these derivatives, retains an activation cache whose size grows with the sum of the layer widths, and general-purpose differentiation runtimes allocate the computational graph from the heap at each call. This paper presents a compiler that evaluates a neural CBF and its exact Lie derivatives by forward-mode dual-number arithmetic. The compiler emits self-contained C++ code in which a single forward pass, without backpropagation, returns the barrier value and its exact Lie derivative along a given vector field; the drift and input Lie derivatives of the safety constraint are obtained from one such pass per vector field, and a second-order extension based on hyper-dual numbers returns the exact second-order Lie derivatives required by CBFs of relative degree two. The dual forward pass requires a workspace bounded by four times the widest layer, independent of network depth, and the emitted code contains no allocation call sites, so the absence of dynamic allocation is verifiable by inspection of the code. On an ESP32-S3 microcontroller, the compiled filter assembles the complete safety constraint in under one millisecond from statically allocated buffers of at most 768 bytes, and the maximum execution time over 1000 evaluations lies within 5% of the median in all three examples, whereas a heap-allocating reverse-mode baseline shows maxima 33% and 70% above its median in the two first-order examples. The compiler and the embedded experiments are released as open-source software.

eess.SY