Search arXiv⌕ Search

arXiv subjects

Sung-il Kim

Publications and source records attributed to Sung-il Kim.

4 recordsLinked to original sources

A four-level executable validation protocol for evaluating LLM-generated topology specifications of physics-based HVAC digital twins

Physics-based digital twins of air conditioning, a principal energy consumer in manufacturing and buildings, can be generated automatically from a declarative specification of its equipment, connections, and sizing. Large language models (LLMs) now write such specifications from plain-language descriptions. Evaluations of these specifications stop at parse success, completed runs, or textual similarity, and cannot reject a model that converges in simulation but is physically wrong. In this study, a four-level protocol is proposed that tests whether an LLM-written specification not only executes but also yields a physically valid digital twin. Each specification is executed through static validity, model build, simulation convergence, and behavioral equivalence with a hidden reference model within bands calibrated by $\pm$20% sizing perturbations. The protocol was applied to eight LLMs and fourteen HVAC topologies, five describing an existing low-humidity test chamber. To test for authorship bias, engineers and a second model family also described six topologies. Within three repairs, seven of eight models built in 98.6 to 100% of trials, with simulations converging in at least 80.0%, but reached behavioral equivalence in only 50.0 to 98.6%. About half of the failed trials converged, but not to the reference steady state, mostly in desiccant rotor systems. Pooled pass rates varied by under five percentage points across description authors. These results imply that the physics hardest to model in each field, here the desiccant rotor, must enter the generation framework as validation levels. The protocol can be adapted to other fields that generate executable digital twins from declarative specifications.

eess.SY↗

Binder migration across film consolidation and pore emptying in electrode drying: a continuous model validated against drying-rate, thickness, and schedule experiments

Drying battery electrodes faster saves energy but drives dissolved binder toward the film surface, depleting the current-collector interface and weakening adhesion. Models of this migration stop convecting the binder when film consolidation ends, and models of the subsequent pore emptying omit the binder or start from an assumed binder field, so no simulation has followed binder convection through both stages that a drying schedule acts on. This study presents a continuous simulation of the dissolved binder field across both stages, driven by the published drying rates and completed by effective descriptions of the two questions the base transport physics leaves open: where the liquid of the consolidating film carries the binder, and when the binder stops moving as the pores empty. With a single parameter set, the simulation reproduces three types of published measurements: the change of the surface-to-interface binder ratio with drying rate over a factor of 5.6 and the surface and interface binder levels of films six times thicker; concentration profiles through the film interior; and the response of the interface binder to the time at which the drying rate is switched mid-process. Applied without further adjustment to a published three-stage schedule, the model reproduces the shortened drying and the full interface recovery when the rate is lowered early, and shows that its final high-rate stage begins after the binder has stopped. Combined with a coater-scale process model, the model can be used to identify operating points for electrode production that improve energy efficiency and product quality together.

cs.CE↗

Narrow and Deep: An Ontology Tower as the Knowledge of an LLM Agent for an Industrial Equipment System

Large language model (LLM) agents are beginning to operate industrial energy equipment, and what they get right depends on what they are told about the plant. Established building ontologies name many kinds of points across many sites, whereas an industrial equipment system needs few entities with much knowledge about each. This study proposes the ontology tower, a narrow-and-deep ontology of a single equipment system whose knowledge deepens in two ways: through quantities derived from the measured points by physical relations, and through lessons from the operating journal incorporated as knowledge nodes. On a real low-humidity air-handling test plant operated daily through a programmable logic controller, agents received a text projected from its tower in a preregistered evaluation of nine tasks replayed from the plant's records, using four open-weight models from 9 to about 750 billion parameters. This knowledge raised the rate at which the agents avoided the most plausible misjudgment of each task by about 20 percentage points, and the overall task score of the 9-billion-parameter model as much as that of the largest. Operating lessons were used when incorporated into the tower or placed in the prompt as records, but seldom when left in the journal behind a search tool. In live runs through an invariant safety layer, the agents brought the controlled variable into its target band in 12 of 14 runs. An ontology narrow in entities but deep in what is known about them can thus supply the knowledge that an agent for an industrial equipment system needs.

eess.SY↗

Automated generation of experimentally validated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications

In battery manufacturing, the low-dew-point air conditioning of dry rooms is among the largest energy consumers, and a physics-based digital twin offers insight for operating-point optimization beyond the installed monitoring points. Building one and calibrating it to field data each demand distinct expertise, which limits industrial uptake. We present a framework that generates a dynamic digital twin of an HVAC system from a declarative topology specification, concise enough to draft from a natural-language plant description, compiled against a purpose-built physical component library with wiring, solver, and telemetry synthesized automatically. The models carry equipment-level physics: the desiccant wheel couples heat and mass transfer through an interchangeable sorption-isotherm component, so an undisclosed commercial sorbent is calibrated as an effective isotherm rather than asserted as a material. For experimental validation we built an industrial-grade, ten-component low-dew-point system whose commercial desiccant-wheel unit holds a chamber near -40 °C frost point, and operated it in both dehumidification and bypass regimes. Generation reached a runnable model fifteen times faster than expert manual construction, and a single parameter set, fitted only to three closed-loop humidity nodes, predicts the bypass regime within 0.1 °C, the reactivation-heater power within 5%, and measured input-step responses. Identifiability analysis shows why this is prediction, not fitting: ordinary operating points constrain only one parameter combination, and the deep-dry equilibrium level of the recirculating loop supplies the missing signal. The framework shortens the path from plant description to measurement-validated twin; its criteria-based calibration is a step toward twins calibrated, not only constructed, automatically.

eess.SY↗