EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai, Xiuxiu He, Laura Cervino, Jean Moran, Xiang Li, Tianfang Li, Yabo Fu. 2026-10-27. EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions. https://arxiv.org/abs/2610.37740

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Latent Representation Learning from 3D Brain MRI for Latent Analysis and Prediction in Multiple Sclerosis

Neurological diseases can cause significant cognitive impairment, yet linking brain structure to cognitive function remains challenging due to the limitations of conventional methods and the black-box nature of deep learning. We propose InfoVAE-Med3D, an adaptation of InfoVAE for three-dimensional brain MRI that learns informative latent representations by relaxing the mutual information regularization penalty between inputs and latent representations. We evaluated the method on a healthy control (HC) dataset (\(n=6{,}503\)) with age and sex information and a multiple sclerosis (MS) dataset (\(n=916\)) with age, sex, and Symbol Digit Modalities Test (SDMT) scores. Two-dimensional visualizations revealed sex-related clustering and smooth transitions in grey and white matter volumes. Removing the mutual information regularization penalty generally improved MRI reconstruction and brain age and SDMT prediction using support vector regression, outperforming other variational autoencoder variants and achieving competitive performance with deep learning predictors, particularly on the MS dataset. InfoVAE-Med3D provides informative latent representations for investigating brain-related characteristics and supports latent-space analysis and imaging biomarker discovery for cognitive impairment, particularly in MS.

eess.IV↗

EvoPS: Evolutionary Patch Selection for Whole Slide Image Analysis in Computational Pathology

In computational pathology, the gigapixel scale of Whole-Slide Images (WSIs) necessitates their division into thousands of smaller patches. Analyzing these high-dimensional patch embeddings is computationally expensive and risks diluting key diagnostic signals with many uninformative patches. Existing patch selection methods often rely on random sampling or simple clustering heuristics and typically fail to explicitly manage the crucial trade-off between the number of selected patches and the accuracy of the resulting slide representation. To address this gap, we propose EvoPS (Evolutionary Patch Selection), a novel framework that formulates patch selection as a multi-objective optimization problem and leverages an evolutionary search to simultaneously minimize the number of selected patch embeddings and maximize the performance of a downstream similarity search task, generating a Pareto front of optimal trade-off solutions. We validated our framework across four major cancer cohorts from The Cancer Genome Atlas (TCGA) using five pretrained deep learning models to generate patch embeddings, including both supervised CNNs and large self-supervised foundation models. The results demonstrate that EvoPS can reduce the required number of training patch embeddings by over 90% while consistently maintaining or even improving the final classification F1-score compared to a baseline that uses all available patches' embeddings selected through a standard extraction pipeline. The EvoPS framework provides a robust and principled method for creating efficient, accurate, and interpretable WSI representations, empowering users to select an optimal balance between computational cost and diagnostic performance.

eess.IV↗

Calibrated Selective Prediction Using Deep Ensembles for ROI-Based Thyroid Nodule Ultrasound Classification Under Dataset Shift: A Retrospective Evaluation

Background: Deep learning models can classify thyroid nodules on ultrasound, but reliable clinical decision support also requires calibrated probabilities, uncertainty estimation, and selective referral, particularly under dataset shift. Methods: We developed a calibrated deterministic five-member deep ensemble for ROI-based thyroid nodule classification and selective image-based triage. TN5000 was used for model development, five-fold cross-validation, member-wise vector-scaling calibration, and fold-specific threshold selection. TN3K served as an independent external dataset-shift evaluation. The framework used ConvNeXt-Tiny with squeeze-and-excitation attention, ensemble-mean malignancy probability, and mutual information (MI) as an ensemble-disagreement score. A three-tier policy assigned images to No-FNA suggestion, FNA recommendation, or radiologist review. Results: On pooled out-of-fold TN5000 predictions, the ensemble achieved AUC-ROC 0.9395, AP 0.9715, ECE 0.0088, and Brier score 0.0813. At 50% nominal MI retention, 7.2% of cases received a No-FNA suggestion, 39.9% an FNA recommendation, and 52.9% radiologist review, with 98.3% No-FNA NPV and 99.83% malignancy capture. On TN3K, AUC-ROC decreased to 0.7870, AP to 0.7254, ECE increased to 0.1899, and Brier score to 0.2281. The frozen TN5000 policy assigned 83.7% to review, 1.0% to No-FNA, and 15.3% to FNA recommendation. No malignant image entered the No-FNA pathway, but FNA-recommendation PPV fell to 76.6%. Conclusion: The framework showed strong internal discrimination and calibration, but limited external threshold transportability. Selective prediction may help identify images unsuitable for automated triage, but local recalibration, threshold validation, and prospective clinical evaluation are required before deployment.

eess.IV↗