Simultaneous 3D acoustic modulation and imaging of proton-induced nanodroplet vaporization for proton therapy monitoring

Abstract

Superheated nanodroplets exposed to ionizing radiation vaporize into echogenic microbubbles, enabling ultrasound-based radiation therapy monitoring and proton range verification. However, at body temperature, decafluorobutane nanodroplets are insensitive to primary protons, and vaporize only when traversed by rare heavy secondary particles, limiting the in vivo applicability of this concept. We previously demonstrated that acoustic modulation at pressures well below the Acoustic Droplet Vaporization threshold can transiently increase nanodroplet sensitivity to radiation, enabling vaporization by primary protons. However, as acoustic modulation was applied by a focused single-element transducer, sensitization was restricted to a small region of the irradiated volume, and monitoring required an additional imaging probe. Here, we introduce a compact implementation that combines wide-field acoustic modulation and volumetric imaging on the same large-element matrix array, enabling simultaneous nanodroplet sensitization to protons and vaporization monitoring across the entire irradiated volume. The resulting 3D vaporization maps were fitted to the proton stopping distribution to estimate beam position and width parameters. At body temperature and starting from acoustic pressures as low as 122 kPa, we observed a transition from a response dominated by secondary particles to a response dominated by primary protons. The resulting vaporization peak at the proton range enabled sub-millimeter range estimation and detection of a 1.05 mm range shift with both accuracy and precision below 0.2 mm. These results demonstrate proton range verification and 3D treatment monitoring with acoustically-modulated decafluorobutane nanodroplets and represent an important step towards the envisioned clinical application.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sophie V. Heymans, Bram Carlier, Marcus Ingram, Kenneth Poels, Marc Desmaret, Nicolas Gerard, Alessandro Ramalli, Marc Fournelle, Tom Depuydt, Edmond Sterpin, Jan D'hooge, Koen Van Den Abeele. 2026-11-07. Simultaneous 3D acoustic modulation and imaging of proton-induced nanodroplet vaporization for proton therapy monitoring. https://searcharxiv.org/abs/2611.10757

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

physics.med-ph↗

Fast ungated five-dimensional cardiac MRI on a 1.5 T MR-linac for MRI-guided radiotherapy

Background: Stereotactic arrhythmia radiotherapy (STAR) for patients with ventricular tachycardia is currently limited by complex cardiorespiratory motion. Current 5D-MRI motion models require long acquisition and reconstruction times, limiting clinical viability. Objective: To develop a fast, ungated 5D-MRI reconstruction method for personalized motion characterization to support MRI-guided STAR treatments. Methods: We propose a fast, ungated 5D-MRI reconstruction method based on the CMR-MOTUS framework. The method uses a 3D Cartesian acquisition with a joint optimization framework to reconstruct a motion-corrected reference image and low-rank deformation vector fields (DVFs). By exploiting the low rank structure, we explicitly disentangle respiratory and cardiac motion during optimization. Then, the DVFs are used for 5D-MRI reconstruction with a retrospectively adjustable number of motion states. Validation was performed using digital and physical cardiorespiratory phantoms. Furthermore, the approach was evaluated using 10 healthy volunteers, comparing motion consistency with 2D cine MRI. Results: Validation of 5D CMR-MOTUS using digital and physical phantoms demonstrated accurate 5D-MRI reconstruction. In the physical phantom, 5D CMR-MOTUS achieved a left-ventricle DICE of 0.96 +/- 0.01. In the volunteer cohort, the 5D-MRI scans showed strong motion to 2D cine MRI, with a cardiac motion error of 0.1 +/- 0.9 mm and a respiratory motion error of 0.2 +/- 2.9 mm. Crucially, 5D-MRI data were acquired in 1 minute and reconstructed in 6 minutes. Conclusions: The proposed 5D-MRI method enables rapid, high-quality, and personalized motion characterization, demonstrating potential for integration into MRI-guided STAR treatments. Data Availability: The 3D k-space data and 5D reconstructions for the ten volunteers are publicly available at https://doi.org/10.5281/zenodo.21278894

physics.med-ph↗

Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of concept

The long-term success of spinal instrumentation depends on the initial stability of pedicle screws (PS), yet current intraoperative assessments rely on surgeon subjectivity. This study introduces a quantitative, non-invasive approach-the Impact-Based Analysis Method (IBAM)-to support intraoperative decision-making. The IBAM measures screw stability using low-amplitude impacts delivered with an instrumented hammer on the surgical screwdriver after screw insertion. An IBAM indicator, defined as the average time difference between the two earliest local maxima in the force signal, was analyzed under varying stability conditions in artificial bone samples. Experimental factors included bone density ($ρ$), insertion depth ( D ), and pilot hole diameter ( $Φ$ ). The IBAM indicator was compared with the PS pull-out force for each configuration. Although the main effects showed opposite trends for the pull-out force and the IBAM indicator, their relative magnitudes were similar ( $ρ$ $\sim$35%, D $\sim$25%, $Φ$ $\sim$15%). The relationship between the pull-out force and the IBAM indicator followed a power-law model (adjusted R 2 =___0.85) with a negative exponent. As screw stability increased, the pull-out force rose while the IBAM indicator decreased, demonstrating complementary sensitivity to bone-implant interface changes. While results are promising, the simplified experimental design limited the ability to fully capture bone-implant interaction complexity. Future studies should aim to validate IBAM in vivo to confirm its clinical applicability..

physics.med-ph↗