Search arXivSearch

arXiv subjects

Anthony Butler

Publications and source records attributed to Anthony Butler.

4 recordsLinked to original sources

A solution for co-locating 2D histology images in 3D for histology-to-CT and MR image registration: closing the loop for bone sarcoma treatment planning

This work presents a proof-of-concept solution designed to improve the accuracy of radiographic feature characterisation in pre-surgical CT/MR volumes. The solution involves 3D co-location of 2D digital histology slides within ex-vivo, tumour tissue CT volumes. In the initial step, laboratory measurements obtained during histology dissection were used to seed the placement of the individual histology slices in corresponding tumour tissue CT volumes. The process was completed by aligning corresponding bone in histology images to bone in the CT using in-plane point-based registration. Six bisected canine humerus datasets of ex-vivo CT and corresponding measurements were used to validate dissection placements. Digital seeding exhibited a plane misalignment of 0.19 +- 1.8 mm. User input sensitivity caused 0.08 +- 0.2 mm in plane translation and between 0 and 1.6 degrees deviation. These are of similar magnitude to reported misalignment of 0.9-1.3 mm and 1.1-1.9 degrees in related prostate histology co-location [1]. Although this work only reported on animal femur sarcoma CT images and histology slide images, the solution can be generalised to various sarcoma geometries and presentation sites. Furthermore, the solution co-locates high-fidelity data to advance tissue characterisation with minimal disruption to existing clinical workflows. Improved tissue characterisation accuracy, supported by the resolution of histology images, can enhance surgical planning accuracy and patient outcomes by bringing the insights offered by histology closer to the start of the presentation-diagnosis-planning-surgery-recovery loop.

eess.IV

Deep Few-view High-resolution Photon-counting CT at Halved Dose for Extremity Imaging

X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR volumetric PCCT reconstruction has been challenged by the large memory burden, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed validated in a New Zealand clinical trial. Specifically, we design a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and clinical data. Our results in a reader study of 8 patients from the clinical trial demonstrate a great potential to cut the radiation dose to half that of the clinical PCCT standard without compromising image quality and diagnostic value.

physics.med-ph

Motion Correction via Locally Linear Embedding for Helical Photon-counting CT

X-ray photon-counting detector (PCD) offers low noise, high resolution, and spectral characterization, representing a next generation of CT and enabling new biomedical applications. It is well known that involuntary patient motion may induce image artifacts with conventional CT scanning, and this problem becomes more serious with PCD due to its high detector pitch and extended scan time. Furthermore, PCD often comes with a substantial number of bad pixels, making analytic image reconstruction challenging and ruling out state-of-the-art motion correction methods that are based on analytical reconstruction. In this paper, we extend our previous locally linear embedding (LLE) cone-beam motion correction method to the helical scanning geometry, which is especially desirable given the high cost of large-area PCD. In addition to our adaption of LLE-based parametric searching to helical cone-beam photon-counting CT geometry, we introduce an unreliable-volume mask to improve the motion estimation accuracy and perform incremental updating on gradually refined sampling grids for optimization of both accuracy and efficiency. Our numerical results demonstrate that our method reduces the estimation errors near the two longitudinal ends of the reconstructed volume and overall image quality. The experimental results on clinical photon-counting scans of the patient extremities show significant resolution improvement after motion correction using our method, which reveals subtle fine structures previously hidden under motion blurring and artifacts.

physics.med-ph

Design, Implementation and First Measurements with the Medipix Neutron Camera in CMS

The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.

physics.ins-det