Search arXiv⌕ Search

arXiv subjects

Fabian Isensee

Publications and source records attributed to Fabian Isensee.

At least 19 recordsLinked to original sources

Dataset Collections: Challenges of Large-Scale Data Aggregation in 3D Medical Image Datasets

The development of deep learning-based medical AI depends on high-quality annotated data. Yet, dataset creation remains constrained by the need for expert radiologist annotations, limiting curated datasets to relatively small cohorts. To overcome this limitation, recent efforts increasingly aggregate disparate public datasets into large-scale dataset collections. However, combining datasets at scale often obscures data provenance, introducing substantial risks of reuse propagation, unintended leakage, bias amplification and distorted data distributions. In this work, we study these problems on a massive collection of 565k 3D radiological images across 1034 public datasets and provide practical resources to address them. Firstly, we formalize dataset collections as a distinct paradigm in medical image analysis and characterize their structural challenges, including reuse propagation, duplication, and provenance fragmentation. Secondly, we perform a large-scale empirical study of duplication on this collection and demonstrate extensive exact and near-duplicate reuse across public datasets via perceptual hashing and manual tracing, identifying a lower bound of 118k duplicate pairs. We make the perceptual hashes publicly accessible for comparison through our website, providing researchers with a standardized reference for identifying potential overlaps and shared provenance. Thirdly, since hashing alone cannot detect all duplicates, we introduce MAP (Metadata for Aggregation and Provenance), a lightweight, portable metadata profile for documenting provenance, known overlaps, and deduplication decisions in dataset collections. Our contributions help dataset collections shift from coarse aggregations to reliable and provenance-aware data scaling mechanisms in medical image analysis. A web tool supporting our work is available at https://mic-dct.dkfz.de/.

eess.IV↗

nnInteractive Agent: General-Purpose AI Agents as 3D Image Annotators

Interactive 3D segmentation models such as nnInteractive turn a few spatial prompts (points, scribbles, boxes) into accurate volumetric masks, but a human still does the annotation work: finding each structure, placing prompts, checking the result and correcting it. General-purpose AI agents can now interpret images, call tools and write code. We show that such agents can take over this work without additional training: the user makes a request in plain language, and the agent works out what has to be segmented, locates the targets, prompts nnInteractive, inspects the 3D result, corrects it and responds to feedback. Asked for 'the muscles used for chewing', an agent identifies and segments the masseters and pterygoids; asked to count liver lesions, it writes its own code to find candidates and splits a merged lesion on request. Our open-source nninteractive-agent provides nnInteractive as tools over the Model Context Protocol (MCP), together with a skill that encodes how experienced users prompt it. On a benchmark spanning CT, MRI, PET and micro-CT of humans, a mouse and an ant (14 images; 51 targets from organs and tumours to muscles, foot bones, vessel trees and an insect brain), Claude Code and Codex reach a mean Dice of 0.81 and 0.84 from the request alone; when told where each target is, both reach 0.85 and prompt nearly as effectively as an oracle that places prompts using the reference segmentation. A text-prompted 3D model (VoxTell) is more accurate on most standard radiological targets but less robust: it returns an empty mask for one of them and fails on the leg muscles, the foot bones, the mouse and the ant, where the agents remain accurate. Code: https://github.com/MIC-DKFZ/nninteractive-agent

cs.LG↗

nnFoundation: 3D Foundation Models for Radiology

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

cs.CV↗

The TopCoW Challenge -- Topology-Aware Circle of Willis Segmentation for CT and MR Angiography

The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain. Its vascular architecture is believed to influence the risk, severity, and outcome of serious neurovascular diseases. However, characterizing the highly variable CoW anatomy remains a manual and time-consuming expert task. The CoW is commonly imaged by two non-invasive angiographic imaging modalities, magnetic resonance angiography (MRA) and computed tomography angiography (CTA), yet few datasets with annotated CoW anatomy exist, and there have been no established benchmarks for comparing CoW segmentation algorithms. We organized the TopCoW benchmark challenge alongside the release of an annotated CoW dataset with 125 paired MRA and CTA scans from the same patients. Voxel-level annotations for 13 vessel components were created using virtual reality technology and verified by clinical experts. Participants submitted algorithms for CoW segmentation and variant classification, which we evaluated on internal and external test sets comprising 226 scans from over five centers. The benchmark includes voxel-level segmentation, CoW component detection, CoW variant classification, and two clinical application tasks. We received submissions from over 250 participants across six continents. Top-performing teams achieved over 90% Dice scores for CoW segmentation, over 80% F1 scores for detecting key vessel components, and over 70% balanced accuracy in CoW variant classification across nearly all test sets. The best algorithms also supported clinically relevant downstream tasks by accurately classifying fetal-type posterior cerebral arteries and localizing aneurysms in relation to CoW anatomy. This benchmark demonstrated the utility of CoW segmentation algorithms for some downstream clinical applications with explainability.

cs.CV↗

Lost in the Folds: When Cross-Validation Is Not a Deep Ensemble for Uncertainty Estimation

Ensemble disagreement is widely used as a proxy for epistemic uncertainty in medical image segmentation. In practice, many studies form ensembles via K-fold cross-validation (CV), yet refer to them as ``deep ensembles'' (DE). Because CV members are trained on different data subsets, their disagreement mixes seed-driven variability with data-exposure effects, which can change how uncertainty should be interpreted. We audit recent segmentation uncertainty studies and find that terminology--implementation mismatches are common. We then compare a standard 5-fold CV ensemble to a 5-member DE (fixed training set, different random seeds) under otherwise identical configurations on three multi-rater segmentation datasets spanning three modalities. We evaluate uncertainty for calibration, failure detection, ambiguity modeling, and robustness under distribution shift. DE match segmentation accuracy while improving calibration and failure detection, whereas CV ensembles sometimes correlate more strongly with inter-rater variability on the studied datasets. Thus, ensemble construction should be chosen to match the research question: DE for reliability-oriented use (e.g., selective referral/failure detection) and CV ensembles as a proxy for ambiguity. We provide a lightweight nnU-Net modification enabling DE training within the default pipeline.

cs.CV↗

TriALS: Triphasic-Aided Liver Lesion Segmentation Benchmark in Non-Contrast CT

Automated segmentation of liver lesions on non-contrast computed tomography (NCCT) is clinically important but fundamentally challenging, particularly in low-resource settings across Africa and Asia where contrast agents are frequently unavailable. Progress has been limited by the absence of annotated NCCT benchmarks. Here we describe the TriALS challenge for automated liver lesion segmentation under contrast-limited conditions, supported by a multi-centre dataset of 150 cases with four-phase CT acquisitions (600 volumes) from Egyptian and Chinese institutions. Algorithms were evaluated on 70 cases from three institutions, including an independent external cohort. The top-performing method achieved a mean venous-phase Dice of 0.754, consistent with human-level performance, yet dropped to 0.57 on NCCT. On external validation, the leading method outperformed off-the-shelf models by up to 28% in Dice on NCCT. Algorithm performance was most strongly predicted by training data scale and pre-training strategy. A cross-year comparison exposed a persistent perceptual barrier on NCCT that scaling pre-training alone cannot overcome. Data, annotations, and code are available at https://github.com/xmed-lab/TriALS.

cs.CV↗

The autoPET3 Challenge: Automated Lesion Segmentation in Whole-Body PET/CT $\unicode{x2013}$ Multitracer Multicenter Generalization

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1,014 [18F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [18F]/[68Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, constituting the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer-center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category isolated the contribution of data handling strategies by restricting participants to a fixed baseline model. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5 mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and probably approaching reader agreement; (2) compositional generalization to unseen tracer-center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.

cs.CV↗

Primus: Enforcing Attention Usage for 3D Medical Image Segmentation

Transformers have achieved remarkable success across multiple fields, yet their impact on 3D medical image segmentation remains limited with convolutional networks still dominating major benchmarks. In this work, (A) we analyze current Transformer-based segmentation models and identify critical shortcomings, particularly their over-reliance on convolutional blocks. Further, we demonstrate that in some architectures, performance is unaffected by the absence of the Transformer, thereby demonstrating their limited effectiveness. To address these challenges, we move away from hybrid architectures and (B) introduce Transformer-centric segmentation architectures, termed Primus and PrimusV2. Primus leverages high-resolution tokens, combined with advances in positional embeddings and block design, to maximally leverage its Transformer blocks, while PrimusV2 expands on this through an iterative patch embedding. Through these adaptations, Primus surpasses current Transformer-based methods and competes with a default nnU-Net while PrimusV2 exceeds it and is on par with the state-of-the-art CNNs such as ResEnc-L and MedNeXt architectures across nine public datasets. In doing so, we introduce the first competitive Transformer-centric model, making Transformers state-of-the-art in 3D medical image segmentation. The code is available here: https://github.com/MIC-DKFZ/nnUNet/blob/master/documentation/primus.md.

cs.CV↗

nnLandmark: A Self-Configuring Method for 3D Medical Landmark Detection

Landmark detection is central to many medical applications, such as identifying critical structures for treatment planning or defining control points for biometric measurements. However, manual annotation is labor-intensive and requires expert anatomical knowledge. While deep learning shows promise in automating this task, fair evaluation and interpretation of methods in a broader context are hindered by limited public benchmarking, inconsistent baseline implementations, and non-standardized experimentation. To overcome these pitfalls, we present nnLandmark, a self-configuring framework for 3D landmark detection that combines tailored heatmap generation, loss design, inference logic, and a robust set of hyperparameters for heatmap regression, while reusing components from nnU-Net's underlying self-configuration and training engine. nnLandmark achieves state-of-the-art performance across five public and one private dataset, benchmarked against three recently published methods. Its out-of-the-box usability enables training strong landmark detection models on new datasets without expert knowledge or dataset-specific hyperparameter tuning. Beyond accuracy, nnLandmark provides both a strong, common baseline and a flexible, standardized environment for developing and evaluating new methodological contributions. It further streamlines evaluation across multiple datasets by offering data conversion utilities for current public benchmarks. Together, these properties position nnLandmark as a central tool for advancing 3D medical landmark detection through systematic, transparent benchmarking, enabling to genuinely measure methodological progress. The code is available on GitHub: https://github.com/MIC-DKFZ/nnLandmark

cs.CV↗

Finally Outshining the Random Baseline: A Simple and Effective Solution for Active Learning in 3D Biomedical Imaging

Active learning (AL) has the potential to drastically reduce annotation costs in 3D biomedical image segmentation, where expert labeling of volumetric data is both time-consuming and expensive. Yet, existing AL methods are unable to consistently outperform improved random sampling baselines adapted to 3D data, leaving the field without a reliable solution. We introduce Class-stratified Scheduled Power Predictive Entropy (ClaSP PE), a simple and effective query strategy that addresses two key limitations of standard uncertainty-based AL methods: class imbalance and redundancy in early selections. ClaSP PE combines class-stratified querying to ensure coverage of underrepresented structures and log-scale power noising with a decaying schedule to enforce query diversity in early-stage AL and encourage exploitation later. In our evaluation on 24 experimental settings using four 3D biomedical datasets within the comprehensive nnActive benchmark, ClaSP PE is the only method that generally outperforms improved random baselines in terms of both segmentation quality with statistically significant gains, whilst remaining annotation efficient. Furthermore, we explicitly simulate the real-world application by testing our method on four previously unseen datasets without manual adaptation, where all experiment parameters are set according to predefined guidelines. The results confirm that ClaSP PE robustly generalizes to novel tasks without requiring dataset-specific tuning. Within the nnActive framework, we present compelling evidence that an AL method can consistently outperform random baselines adapted to 3D segmentation, in terms of both performance and annotation efficiency in a realistic, close-to-production scenario. Our open-source implementation and clear deployment guidelines make it readily applicable in practice. Code is at https://github.com/MIC-DKFZ/nnActive.

cs.CV↗

Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-ray: Summary of the PENGWIN 2024 Challenge

The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.

eess.IV↗

MedNeXt-v2: Scaling 3D ConvNeXts for Large-Scale Supervised Representation Learning in Medical Image Segmentation

Large-scale supervised pretraining is rapidly reshaping 3D medical image segmentation. However, existing efforts focus primarily on increasing dataset size and overlook the question of whether the backbone network is an effective representation learner at scale. In this work, we address this gap by revisiting ConvNeXt-based architectures for volumetric segmentation and introducing MedNeXt-v2, a compound-scaled 3D ConvNeXt that leverages improved micro-architecture and data scaling to deliver state-of-the-art performance. First, we show that routinely used backbones in large-scale pretraining pipelines are often suboptimal. Subsequently, we use comprehensive backbone benchmarking prior to scaling and demonstrate that stronger from scratch performance reliably predicts stronger downstream performance after pretraining. Guided by these findings, we incorporate a 3D Global Response Normalization module and use depth, width, and context scaling to improve our architecture for effective representation learning. We pretrain MedNeXt-v2 on 18k CT volumes and demonstrate state-of-the-art performance when fine-tuning across six challenging CT and MR benchmarks (144 structures), showing consistent gains over seven publicly released pretrained models. Beyond improvements, our benchmarking of these models also reveals that stronger backbones yield better results on similar data, representation scaling disproportionately benefits pathological segmentation, and that modality-specific pretraining offers negligible benefit once full finetuning is applied. In conclusion, our results establish MedNeXt-v2 as a strong backbone for large-scale supervised representation learning in 3D Medical Image Segmentation. Our code and pretrained models are made available with the official nnUNet repository at: https://www.github.com/MIC-DKFZ/nnUNet

eess.IV↗

Expectation-Maximization as the Engine of Scalable Medical Intelligence

Large, high-quality, annotated datasets are the foundation of medical AI research, but constructing even a small, moderate-quality, annotated dataset can take years of effort from multidisciplinary teams. Although active learning can prioritize what to annotate, scaling up still requires extensive manual efforts to revise the noisy annotations. We formulate this as a missing-data problem and develop ScaleMAI, a framework that unifies data annotation and model development co-evolution through an Expectation-Maximization (EM) process. In this iterative process, the AI model automatically identifies and corrects the mistakes in annotations (Expectation), while the refined annotated data retrain the model to improve accuracy (Maximization). In addition to the classical EM algorithm, ScaleMAI brings human experts into the loop to review annotations that cannot be adequately addressed by either Expectation or Maximization step (<5%). As a result, ScaleMAI progressively creates an annotated dataset of 47,315 CT scans (4.8x larger than the largest public dataset, PanTS) including 4,163,720 per-voxel annotations for benign/malignant tumors and 88 anatomical structures. ScaleMAI iteratively trains a model that exceeds human expert performance in tumor diagnosis (+7%), and outperforms models developed from smaller, moderate-quality datasets, with statistically significant gains in tumor detection (+10%) and segmentation (+14%) on two prestigious benchmarks.

cs.CV↗

nnActive: A Framework for Evaluation of Active Learning in 3D Biomedical Segmentation

Semantic segmentation is crucial for various biomedical applications, yet its reliance on large annotated datasets presents a bottleneck due to the high cost and specialized expertise required for manual labeling. Active Learning (AL) aims to mitigate this challenge by querying only the most informative samples, thereby reducing annotation effort. However, in the domain of 3D biomedical imaging, there is no consensus on whether AL consistently outperforms Random sampling. Four evaluation pitfalls hinder the current methodological assessment. These are (1) restriction to too few datasets and annotation budgets, (2) using 2D models on 3D images without partial annotations, (3) Random baseline not being adapted to the task, and (4) measuring annotation cost only in voxels. In this work, we introduce nnActive, an open-source AL framework that overcomes these pitfalls by (1) means of a large scale study spanning four biomedical imaging datasets and three label regimes, (2) extending nnU-Net by using partial annotations for training with 3D patch-based query selection, (3) proposing Foreground Aware Random sampling strategies tackling the foreground-background class imbalance of medical images and (4) propose the foreground efficiency metric, which captures the low annotation cost of background-regions. We reveal the following findings: (A) while all AL methods outperform standard Random sampling, none reliably surpasses an improved Foreground Aware Random sampling; (B) benefits of AL depend on task specific parameters; (C) Predictive Entropy is overall the best performing AL method, but likely requires the most annotation effort; (D) AL performance can be improved with more compute intensive design choices. As a holistic, open-source framework, nnActive can serve as a catalyst for research and application of AL in 3D biomedical imaging. Code is at: https://github.com/MIC-DKFZ/nnActive

cs.CV↗

VoxTell: Free-Text Promptable Universal 3D Medical Image Segmentation

We introduce VoxTell, a vision-language model for text-prompted volumetric medical image segmentation. It maps free-form descriptions, from single words to full clinical sentences, to 3D masks. Trained on 62K+ CT, MRI, and PET volumes spanning over 1K anatomical and pathological classes, VoxTell uses multi-stage vision-language fusion across decoder layers to align textual and visual features at multiple scales. It achieves state-of-the-art zero-shot performance across modalities on unseen datasets, excelling on familiar concepts while generalizing to related unseen classes. Extensive experiments further demonstrate strong cross-modality transfer, robustness to linguistic variations and clinical language, as well as accurate instance-specific segmentation from real-world text. Code is available at: https://www.github.com/MIC-DKFZ/VoxTell

cs.CV↗

Gut decisions based on the liver: A radiomics approach to boost colorectal cancer screening

Non-invasive colorectal cancer (CRC) screening represents a key opportunity to improve colonoscopy participation rates and reduce CRC mortality. This study explores the potential of the gut-liver axis for predicting colorectal neoplasia through liver-derived radiomic features extracted from routine CT images as a novel opportunistic screening approach. In this retrospective study, we analyzed data from 1,997 patients who underwent colonoscopy and abdominal CT. Patients either had no colorectal neoplasia (n=1,189) or colorectal neoplasia (n_total=808; adenomas n=423, CRC n=385). Radiomics features were extracted from 3D liver segmentations using the Radiomics Processing ToolKit (RPTK), which performed feature extraction, filtering, and classification. The dataset was split into training (n=1,397) and test (n=600) cohorts. Five machine learning models were trained with 5-fold cross-validation on the 20 most informative features, and the best model ensemble was selected based on the validation AUROC. The best radiomics-based XGBoost model achieved a test AUROC of 0.810, clearly outperforming the best clinical-only model (test AUROC: 0.457). Subclassification between colorectal cancer and adenoma showed lower accuracy (test AUROC: 0.674). Our findings establish proof-of-concept that liver-derived radiomics from routine abdominal CT can predict colorectal neoplasia. Beyond offering a pragmatic, widely accessible adjunct to CRC screening, this approach highlights the gut-liver axis as a novel biomarker source for opportunistic screening and sparks new mechanistic hypotheses for future translational research.

q-bio.QM↗

Promptable Longitudinal Lesion Segmentation in Whole-Body CT

Accurate segmentation of lesions in longitudinal whole-body CT is essential for monitoring disease progression and treatment response. While automated methods benefit from incorporating longitudinal information, they remain limited in their ability to consistently track individual lesions across time. Task 2 of the autoPET/CT IV Challenge addresses this by providing lesion localizations and baseline delineations, framing the problem as longitudinal promptable segmentation. In this work, we extend the recently proposed LongiSeg framework with promptable capabilities, enabling lesion-specific tracking through point and mask interactions. To address the limited size of the provided training set, we leverage large-scale pretraining on a synthetic longitudinal CT dataset. Our experiments show that pretraining substantially improves the ability to exploit longitudinal context, yielding an improvement of up to 6 Dice points compared to models trained from scratch. These findings demonstrate the effectiveness of combining longitudinal context with interactive prompting for robust lesion tracking. Code is publicly available at https://github.com/MIC-DKFZ/LongiSeg/tree/autoPET.

eess.IV↗

Towards Interactive Lesion Segmentation in Whole-Body PET/CT with Promptable Models

Whole-body PET/CT is a cornerstone of oncological imaging, yet accurate lesion segmentation remains challenging due to tracer heterogeneity, physiological uptake, and multi-center variability. While fully automated methods have advanced substantially, clinical practice benefits from approaches that keep humans in the loop to efficiently refine predicted masks. The autoPET/CT IV challenge addresses this need by introducing interactive segmentation tasks based on simulated user prompts. In this work, we present our submission to Task 1. Building on the winning autoPET III nnU-Net pipeline, we extend the framework with promptable capabilities by encoding user-provided foreground and background clicks as additional input channels. We systematically investigate representations for spatial prompts and demonstrate that Euclidean Distance Transform (EDT) encodings consistently outperform Gaussian kernels. Furthermore, we propose online simulation of user interactions and a custom point sampling strategy to improve robustness under realistic prompting conditions. Our ensemble of EDT-based models, trained with and without external data, achieves the strongest cross-validation performance, reducing both false positives and false negatives compared to baseline models. These results highlight the potential of promptable models to enable efficient, user-guided segmentation workflows in multi-tracer, multi-center PET/CT. Code is publicly available at https://github.com/MIC-DKFZ/autoPET-interactive

cs.CV↗