Search arXiv⌕ Search

arXiv subjects

Fabio Muleri

Publications and source records attributed to Fabio Muleri.

At least 127 records · Page 7Linked to original sources

Analysis of the data from photoelectric gas polarimeters

We review the tools and procedures for the analysis of the data collected by X-ray photoelectric gas polarimeters, like the ones on-board the Imaging X-ray Polarimetry Explorer (IXPE). Although many of such tools are in principle common with polarimeters working at other energy bands, the peculiar characteristics and performance of these devices require a specific approach. We will start from the analysis of the raw data read-out from this kind of instruments, that is, the image of the track of the photoelectron. We will briefly present how such images are processed with highly-specialized algorithms to extract all the information collected by the instrument. These include energy, time of arrival and, possibly, absorption point of the photon, in addition to the initial direction of emission of the photoelectron. The last is the quantity relevant for polarimetry, and we will present different methods to obtain the polarization degree and angle from it. A simple method, used extensively especially during the development phase of X-ray photoelectric gas polarimeters, is based on the construction and fitting of the azimuthal distribution of the photoelectrons. We will discuss that there are several reasons to prefer an analysis based on Stokes parameters, especially when one wants to analyze measurements of real, i.e., not laboratory, sources. These are quantities commonly used at all wavelengths because they are additive, and then operations like background subtraction or the application of calibration are trivial to apply. We will summarize how Stokes parameters can be used to adapt current spectroscopy software based on forward folding fitting to perform spectro-polarimetry. Moreover, we will derive how to properly associate the statistical uncertainty on a polarimetry measurement and the relation with another statistical indicator, which is in the minimum detectable polarization.

astro-ph.IM↗

A weighted analysis to improve the X-ray polarization sensitivity of IXPE

IXPE is a Small Explorer mission that was launched at the end of 2021 to measure the polarization of X-ray emission from tens of astronomical sources. Its focal plane detectors are based on the Gas Pixel Detector, which measures the polarization by imaging photoelectron tracks in a gas mixture and reconstructing their initial directions. The quality of the single track, and then the capability of correctly determining the original direction of the photoelectron, depends on many factors, e.g., whether the photoelectron is emitted at low or high inclination with respect to the collection plane or the occurrence of a large Coulomb scattering close to the generation point. The reconstruction algorithm used by IXPE to obtain the photoelectron emission direction, also calculates several properties of the shape of the tracks which characterize the process. In this paper we compare several such properties and identify the best one to weight each track on the basis of the reconstruction accuracy. We demonstrate that significant improvement in sensitivity can be achieved with this approach and for this reason it will be the baseline for IXPE data analysis.

astro-ph.IM↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch

Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.

astro-ph.IM↗

A significant detection of X-ray Polarization in Sco X-1 with PolarLight and constraints on the corona geometry

We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polarization fraction of $0.043 \pm 0.008$ and a polarization angle of $52.6^\circ \pm 5.4^\circ$. This confirms a previous marginal detection with OSO-8 in the 1970s, and marks Sco X-1 the second astrophysical source with a significant polarization measurement in the keV band. The measured polarization angle is in line with the jet orientation of the source on the sky plane ($54^\circ$), which is supposedly the symmetric axis of the system. Combining previous spectral analysis, our measurements suggest that an optically thin corona is located in the transition layer under the highest accretion rates, and disfavor the extended accretion disk corona model.

astro-ph.HE↗

Calibration of the IXPE instrument

IXPE scientific payload comprises of three telescopes, each composed of a mirror and a photoelectric polarimeter based on the Gas Pixel Detector design. The three focal plane detectors, together with the unit which interfaces them to the spacecraft, are named IXPE Instrument and they will be built and calibrated in Italy; in this proceeding, we will present how IXPE Instrument will be calibrated, both on-ground and in-flight. The Instrument Calibration Equipment is being finalized at INAF-IAPS in Rome (Italy) to produce both polarized and unpolarized radiation, with a precise knowledge of direction, position, energy and polarization state of the incident beam. In flight, a set of four calibration sources based on radioactive material and mounted on a filter and calibration wheel will allow for the periodic calibration of all of the three IXPE focal plane detectors independently. A highly polarized source and an unpolarized one will be used to monitor the response to polarization; the remaining two will be used to calibrate the gain through the entire lifetime of the mission.

astro-ph.IM↗

An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE

The Gas Pixel Detector is an X-ray polarimeter to fly on-board IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and non-monochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

astro-ph.IM↗

The IXPE Instrument Calibration Equipment

The Imaging X-ray Polarimetry Explorer is a mission dedicated to the measurement of X-ray polarization from tens of astrophysical sources belonging to different classes. Expected to be launched at the end of 2021, the payload comprises three mirrors and three focal plane imaging polarimeters, the latter being designed and built in Italy. While calibration is always an essential phase in the development of high-energy space missions, for IXPE it has been particularly extensive both to calibrate the response to polarization, which is peculiar to IXPE, and to achieve a statistical uncertainty below the expected sensitivity. In this paper we present the calibration equipment that was designed and built at INAF-IAPS in Rome, Italy, for the calibration of the polarization-sensitive focal plane detectors on-board IXPE. Equipment includes calibration sources, both polarized and unpolarized, stages to align and move the beam, test detectors and their mechanical assembly. While all these equipments were designed to fit the specific needs of the IXPE Instrument calibration, their versatility could also be used in the future for other projects.

astro-ph.IM↗

Prospects for the polarimetric mapping of the Sgr A molecular cloud complex with IXPE

The X-ray polarization degree of the molecular clouds that surround Sgr A* is expected to be greatly lowered because the polarized reflection emission is mixed with the unpolarized thermal emission that pervades the Galactic center region. Hence, this will be a challenging observation for the upcoming Imaging X-ray Polarimeter Explorer (IXPE). We aim to determine the detectability of four molecular clouds (MC) of the Sgr A complex (MC2, Bridge B2, Bridge E, and G0.11-0.11) in a realistic IXPE pointing of the Sgr A field of view. We assess the Minimum Detectable Polarization (MDP) increase when a MC is off axis. We provide two different strategies to reconstruct the intrinsic cloud polarization once the data will be available. We use the Monte Carlo tool ixpeobssim to simulate IXPE observations of the Sgr A MC complex. We use Chandra maps and spectra to model the diffuse emission in the Galactic center region along with a realistic model of the instrumental and diffuse background. We create synthetic polarization products of the unpolarized emission. We combine them with a test dataset from a simulation of a 2 Ms long IXPE observation to retrieve the intrinsic polarization degree of the MCs. We find that for the MC considered here, the MDP increases by 1-15% with respect to the case in which a cloud is observed on-axis. We successfully retrieve the intrinsic polarization degree in the 4.0-8.0 keV band and line-of-sight distance of one of them taken as an example, G0.11-0.11, by correcting the observed (i.e., for a 2 Ms-long simulation) polarization degree map using either a synthetic dilution map or a Stokes intensity map of the unpolarized emission. With both methods, the position of the cloud along the line-of-sight is derived from the reconstructed polarization degree with an uncertainty of 7 and 4 pc, respectively.

astro-ph.GA↗

The Instrument of the Imaging X-ray Polarimetry Explorer

While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s. The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument. IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

astro-ph.IM↗

Discrimination of background events in the PolarLight X-ray polarimeter

PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing on-source and off-source observations, we find that the two datasets display different distributions on image properties. The boundaries between the source and background distributions are obtained and can be used for background discrimination. Such a means can remove over 70% of the background events measured with PolarLight. This approaches the theoretical upper limit of the background fraction that is removable and justifies its effectiveness. For observations with the Crab nebula, the background contamination decreases from 25% to 8% after discrimination, indicative of a polarimetric sensitivity of around 0.2 Crab for PolarLight. This work also provides insights into future X-ray polarimetric telescopes.

astro-ph.IM↗

X-ray polarimetry of the Crab nebula with PolarLight: polarization recovery after the glitch and a secular position angle variation

We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular emission has a difference of 18.0 +- 4.6 (deg) from that measured 42 years ago with OSO-8, indicating a secular evolution of polarization with either the Crab nebula or pulsar. The long-term variation in PA could be a result of multiple glitches in the history, magnetic reconnection or movement of synchrotron emitting structures in the nebula, or secular evolution of the pulsar magnetic geometry.

astro-ph.HE↗

A Study of background for IXPE

Focal plane X-ray polarimetry is intended for relatively bright sources with a negligible impact of background. However this might not be always possible for IXPE (Imaging X-ray Polarimetry Explorer) when observing faint extended sources like supernova remnants. We present for the first time the expected background of IXPE by Monte Carlo simulation and its impact on real observations of point and extended X-ray sources. The simulation of background has been performed by Monte Carlo based on GEANT4 framework. The spacecraft and the detector units have been modeled, and the expected background components in IXPE orbital environment have been evaluated. We studied different background rejection techniques based on the analysis of the tracks collected by the Gas Pixel Detectors on board IXPE. The estimated background is about 2.9 times larger than the requirement, yet it is still negligible when observing point like sources. Albeit small, the impact on supernova remnants indicates the need for a background subtraction for the observation of the extended sources.

astro-ph.IM↗

Modeling the in-orbit background of PolarLight

PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that the measured background with PolarLight is dominated by high energy electrons, with a minor contribution from protons and the CXB. The simulation reveals that, in the energy range of 2-8 keV, there are roughly 28% of the background events are caused by energy deposit from a secondary electron with an energy of a few keV, in a physical process identical to the detection of X-rays. Thus, this fraction of background cannot be discriminated from X-ray events. The background distribution is uneven on the detector plane, with an enhancement near the edges. The edge effect is because high energy electrons tend to produce long tracks, which are discarded by the readout electronics unless they have partial energy deposits near the edges. The internal background rate is expected to be around 6 x 10^-3 counts/s/cm2 in 2-8 keV if an effective particle discrimination algorithm can be applied. This indicates that the internal background should be negligible for future focusing X-ray polarimeters with a focal size in the order of mm.

astro-ph.IM↗

Re-detection and a Possible Time Variation of Soft X-ray Polarisation from the Crab

The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detection of soft x-ray polarisation after 40 years from the Crab nebula and pulsar with PolarLight, a miniature polarimeter utilising a novel technique onboard a CubeSat. The polarisation fraction of the Crab in the on-pulse phases was observed to decrease after a glitch of the Crab pulsar on July 23, 2019, while that of the pure nebular emission remained constant within uncertainty. The phenomenon may have lasted about 100 days. If the association between the glitch and polarisation change can be confirmed with future observations, it will place strong constraints on the physical mechanism of the high energy emission and glitch of pulsars.

astro-ph.HE↗

In-flight calibration system of Imaging X-ray Polarimetry Explorer

The NASA/ASI Imaging X-ray Polarimetry Explorer, which will be launched in 2021, will be the first instrument to perform spatially resolved X-ray polarimetry on several astronomical sources in the 2-8 keV energy band. These measurements are made possible owing to the use of a gas pixel detector (GPD) at the focus of three X-ray telescopes. The GPD allows simultaneous measurements of the interaction point, energy, arrival time, and polarization angle of detected X-ray photons. The increase in sensitivity, achieved 40 years ago, for imaging and spectroscopy with the Einstein satellite will thus be extended to X-ray polarimetry for the first time. The characteristics of gas multiplication detectors are subject to changes over time. Because the GPD is a novel instrument, it is particularly important to verify its performance and stability during its mission lifetime. For this purpose, the spacecraft hosts a filter and calibration set (FCS), which includes both polarized and unpolarized calibration sources for performing in-flight calibration of the instruments. In this study, we present the design of the flight models of the FCS and the first measurements obtained using silicon drift detectors and CCD cameras, as well as those obtained in thermal vacuum with the flight units of the GPD. We show that the calibration sources successfully assess and verify the functionality of the GPD and validate its scientific results in orbit; this improves our knowledge of the behavior of these detectors in X-ray polarimetry.

astro-ph.IM↗

In-orbit Operation and Performance of the CubeSat Soft X-ray Polarimeter PolarLight

PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.

astro-ph.IM↗

ESA Voyage 2050 white paper: A Polarized View of the Hot and Violent Universe

Since the birth of X-ray Astronomy, spectacular advances have been seen in the imaging, spectroscopic and timing studies of the hot and violent X-ray Universe, and further leaps forward are expected in the future. On the other hand, polarimetry is very much lagging behind: after the measurements of the Crab Nebula and Scorpius X-1, obtained by OSO-8 in the 70s, no more observations have been performed in the classical X-ray band, even if some interesting results have been obtained in hard X-rays and in soft gamma-rays. The NASA/ASI mission IXPE, scheduled for the launch in 2021, is going to provide for the first time imaging X-ray polarimetry in the 2-8 keV band thanks to its photoelectric polarimeter, coupled with ~25'' angular resolution X-ray mirrors. Its orders of magnitude improvement in sensitivity with respect to the OSO-8 Bragg polarimeter implies scientifically meaningful polarimetric measurements for at least the brightest specimens of most classes of X-ray sources. In 2027, the Chinese-led mission eXTP should also be launched. In addition to timing and spectroscopic instruments, eXTP will have on board photoelectric polarimeters very similar to those of IXPE, but with a total effective area 2-3 times larger. Building on IXPE results, eXTP will increase the number of sources for which significant polarimetric measurements could be obtained. However, further progresses, such as exploring a broader energy range, considering a larger effective area, improving the angular resolution, and performing wide-field polarization measurements, are needed to reach a mature phase for X-ray polarimetry. In the first part of this White Paper we will discuss a few scientific cases in which a next generation X-ray Polarimetry mission can provide significant advances. In the second part, a possible concept for a medium-class Next Generation X-ray Polarimetry (NGXP) mission will be sketched.

astro-ph.IM↗

PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector

The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.

astro-ph.IM↗