Search arXiv⌕ Search

arXiv subjects

Hau-Tieng Wu

Publications and source records attributed to Hau-Tieng Wu.

At least 73 records · Page 4Linked to original sources

Denoising Click-evoked Otoacoustic Emission Signals by Optimal Shrinkage

Click-evoked otoacoustic emissions (CEOAEs) are clinically used as an objective way to infer whether cochlear functions are normal. However, because the sound pressure level of CEOAEs is typically much lower than the background noise, it usually takes hundreds, if not thousands of repetitions to estimate the signal with sufficient accuracy. In this paper, we propose to improve the signal-to-noise ratio (SNR) of CEOAE signals within limited measurement time by optimal shrinkage (OS) in two different settings: the covariance-based OS (cOS) and the singular value decomposition (SVD)-based OS (sOS). By simulation and analyzing human CEOAE data, the cOS consistently reduced the noise and enhanced the SNR by 1 to 2 dB from a baseline method (BM) that is based on calculating the median. The sOS achieved an SNR enhancement of 2 to 3 dB in simulation, and demonstrated capability to enhance the SNR in real recordings when the SNR achieved by the BM was below 0 dB. An appealing property of OS is that it produces an estimate of every individual column of the signal matrix. This property makes it possible to investigate CEOAE dynamics across a longer period of time when the cochlear conditions are not strictly stationary.

eess.SP↗

Numerical computation of triangular complex spherical designs with small mesh ratio

This paper provides triangular spherical designs for the complex unit sphere $Ω^d$ by exploiting the natural correspondence between the complex unit sphere in $d$ dimensions and the real unit sphere in $2d-1$. The existence of triangular and square complex spherical $t$-designs with the optimal order number of points is established. A variational characterization of triangular complex designs is provided, with particular emphasis on numerical computation of efficient triangular complex designs with good geometric properties as measured by their mesh ratio. We give numerical examples of triangular spherical $t$-designs on complex unit spheres of dimension $d=2$ to $6$.

stat.ME↗

Airflow recovery from thoracic and abdominal movements using Synchrosqueezing Transform and Locally Stationary Gaussian Process Regression

Airflow signal encodes rich information about respiratory system. While the gold standard for measuring airflow is to use a spirometer with an occlusive seal, this is not practical for ambulatory monitoring of patients. Advances in sensor technology have made measurement of motion of the thorax and abdomen feasible with small inexpensive devices, but estimation of airflow from these time series is challenging. We propose to use the nonlinear-type time-frequency analysis tool, synchrosqueezing transform, to properly represent the thoracic and abdominal movement signals as the features, which are used to recover the airflow by the locally stationary Gaussian process. We show that, using a dataset that contains respiratory signals under normal sleep conditions, an accurate prediction can be achieved by fitting the proposed model in the feature space both in the intra- and inter-subject setups. We also apply our method to a more challenging case, where subjects under general anesthesia underwent transitions from pressure support to unassisted ventilation to further demonstrate the utility of the proposed method.

stat.ML↗

Convergence analysis of Adaptive Locally Iterative Filtering and SIFT method

Adaptive Local Iterative Filtering (ALIF) is a currently proposed novel time-frequency analysis tool. It has been empirically shown that ALIF is able to separate components and overcome the mode-mixing problem. However, so far its convergence is still an open problem, particularly for highly nonstationary signals, due to the fact that the kernel associated with ALIF is non-translational invariant, non-convolutional and non-symmetric. Our first contribution in this work is providing a convergence analysis of ALIF. From the practical perspective, ALIF depends on a robust frequencies estimator, based on which the decomposition can be achieved. Our second contribution is proposing a robust and adaptive decomposition method for noisy and nonstationary signals, which we coined the Synchrosqueezing Iterative Filtering Technique (SIFT). In SIFT, we apply the synchrosqueezing transform to estimate the instantaneous frequency, and then apply the ALIF to decompose a signal. We show numerically the ability of this new approach in handling highly nonstationary signals.

math.NA↗

A persistent homology approach to heart rate variability analysis with an application to sleep-wake classification

Persistent homology (PH) is a recently developed theory in the field of algebraic topology to study shapes of datasets. It is an effective data analysis tool that is robust to noise and has been widely applied. We demonstrate a general pipeline to apply PH to study time series; particularly the instantaneous heart rate time series for the heart rate variability (HRV) analysis. The first step is capturing the shapes of time series from two different aspects -- {the PH's and hence persistence diagrams of its} sub-level set and Taken's lag map. Second, we propose a systematic {and computationally efficient} approach to summarize persistence diagrams, which we coined {\em persistence statistics}. To demonstrate our proposed method, we apply these tools to the HRV analysis and the sleep-wake, REM-NREM (rapid eyeball movement and non rapid eyeball movement) and sleep-REM-NREM classification problems. The proposed algorithm is evaluated on three different datasets via the cross-database validation scheme. The performance of our approach is better than the state-of-the-art algorithms, and the result is consistent throughout different datasets.

eess.SP↗

When Ramanujan meets time-frequency analysis in complicated time series analysis

To handle time series with complicated oscillatory structure, we propose a novel time-frequency (TF) analysis tool that fuses the short time Fourier transform (STFT) and periodic transform (PT). Since many time series oscillate with time-varying frequency, amplitude and non-sinusoidal oscillatory pattern, a direct application of PT or STFT might not be suitable. However, we show that by combining them in a proper way, we obtain a powerful TF analysis tool. We first combine the Ramanujan sums and $l_1$ penalization to implement the PT. We call the algorithm Ramanujan PT (RPT). The RPT is of its own interest for other applications, like analyzing short signal composed of components with integer periods, but that is not the focus of this paper. Second, the RPT is applied to modify the STFT and generate a novel TF representation of the complicated time series that faithfully reflect the instantaneous frequency information of each oscillatory components. We coin the proposed TF analysis the Ramanujan de-shape (RDS) and vectorized RDS (vRDS). In addition to showing some preliminary analysis results on complicated biomedical signals, we provide theoretical analysis about RPT. Specifically, we show that the RPT is robust to three commonly encountered noises, including envelop fluctuation, jitter and additive noise.

eess.SP↗

An Adaptive QRS Detection Algorithm for Ultra-Long-Term ECG Recordings

Background: Accurate detection of QRS complexes during mobile, ultra-long-term ECG monitoring is challenged by instances of high heart rate, dramatic and persistent changes in signal amplitude, and intermittent deformations in signal quality that arise due to subject motion, background noise, and misplacement of the ECG electrodes. Purpose: We propose a revised QRS detection algorithm which addresses the above-mentioned challenges. Methods and Results: Our proposed algorithm is based on a state-of-the-art algorithm after applying two key modifications. The first modification is implementing local estimates for the amplitude of the signal. The second modification is a mechanism by which the algorithm becomes adaptive to changes in heart rate. We validated our proposed algorithm against the state-of-the-art algorithm using short-term ECG recordings from eleven annotated databases available at Physionet, as well as four ultra-long-term (14-day) ECG recordings which were visually annotated at a central ECG core laboratory. On the database of ultra-long-term ECG recordings, our proposed algorithm showed a sensitivity of 99.90% and a positive predictive value of 99.73%. Meanwhile, the state-of-the-art QRS detection algorithm achieved a sensitivity of 99.30% and a positive predictive value of 99.68% on the same database. The numerical efficiency of our new algorithm was evident, as a 14-day recording sampled at 200 Hz was analyzed in approximately 157 seconds. Conclusions: We developed a new QRS detection algorithm. The efficiency and accuracy of our algorithm makes it a good fit for mobile health applications, ultra-long-term and pathological ECG recordings, and the batch processing of large ECG databases.

eess.SP↗

Transient-evoked otoacoustic emission signals predicting outcomes of acute sensorineural hearing loss in patients with Meniere's Disease

Background: Fluctuating hearing loss is characteristic of Meniere's Disease (MD) during acute episodes. However, no reliable audiometric hallmarks are available for counselling the hearing recovery possibility. Aims/Objectives: To find parameters for predicting MD hearing outcomes. Material and Methods: We applied machine learning techniques to analyse transient-evoked otoacoustic emission (TEOAE) signals recorded from patients with MD. Thirty unilateral MD patients were recruited prospectively after onset of acute cochleo-vestibular symptoms. Serial TEOAE and pure-tone audiogram (PTA) data were recorded longitudinally. Denoised TEOAE signals were projected onto the three most prominent principal directions through a linear transformation. Binary classification was performed using a support vector machine (SVM). TEOAE signal parameters, including signal energy and group delay, were compared between improved and nonimproved groups using Welchs t-test. Results: Signal energy did not differ (p = 0.64) but a significant difference in 1-kHz (p = 0.045) group delay was recorded between improved and nonimproved groups. The SVM achieved a cross-validated accuracy of >80% in predicting hearing outcomes. Conclusions and Significance: This study revealed that baseline TEOAE parameters obtained during acute MD episodes, when processed through machine learning technology, may provide information on outer hair cell function to predict hearing recovery.

eess.SP↗

Novel imaging revealing inner dynamics for cardiovascular waveform analysis via unsupervised manifold learning

Cardiovascular waveforms contain information for clinical diagnosis. By "learning" and organizing the subtle change of waveform morphology from large amounts of raw waveform data, unsupervised manifold learning helps delineate a high-dimensional structure and display it as a novel three-dimensional (3D) image. We investigate the electrocardiography (ECG) waveform for ischemic heart disease and arterial blood pressure (ABP) waveform in dynamic vasoactive episodes. We model each beat or pulse to be a point lying on a manifold, like a surface, and use the diffusion map (DMap) to establish the relationship among those pulses. For ECG datasets, first we analyzed the non-ST-elevation ECG waveform distribution from unstable angina to healthy control, and we investigated intraoperative ST-elevation ECG waveforms to show the dynamic ECG waveform changes. For ABP datasets, we analyzed waveforms collected under endotracheal intubation and administration of vasodilator. To quantify the dynamic separation, we applied the support vector machine (SVM) analysis and the trajectory analysis. For the non-ST-elevation ECG, a hierarchical tree structure comprising consecutive ECG waveforms spanning from unstable angina to healthy control is presented in the 3D image (accuracy=97.6%, macro-F1=96.1%). The DMap helps quantify and visualize the evolving direction of intraoperative ST-elevation myocardial episode in a 1-hour period (accuracy=97.58%, macro-F1=96.06%). The ABP waveform analysis of Nicardipine administration shows inter-individual difference (accuracy=95.01%, macro-F1=96.9%) and their common directions from intra-individual moving trajectories. The dynamic change of the ABP waveform during endotracheal intubation shows a loop-like trajectory structure, which can be further divided using the knowledge obtained from Nicardipine. The 3D images provide clues of underneath physiological mechanisms.

q-bio.QM↗

Can a composite heart rate variability biomarker shed new insights about autism spectrum disorder in school-aged children?

High-frequency heart rate variability (HRV) has identified parasympathetic nervous system alterations in autism spectrum disorder (ASD). In a cohort of school-aged children with and without ASD, we test a set of alternative linear and nonlinear HRV measures, including phase rectified signal averaging, applied to a segment of resting ECG, for associations with ASD vs. other psychiatric conditions. Using machine learning, we identify HRV measures derived from time, frequency, and geometric signal-analytical domains that (1) identify children with ASD relative to peers with receiver operating curve area of .89, and (2) differentiate such children from those with conduct problems or depression. Despite the small cohort and lack of prospective external validation, these preliminary results warrant larger prospective validation studies.

q-bio.QM↗

Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data

Object: It is increasingly popular to collect as much data as possible in the hospital setting from clinical monitors for research purposes. However, in this setup the data calibration issue is often not discussed and, rather, implicitly assumed, while the clinical monitors might not be designed for the data analysis purpose. We hypothesize that this calibration issue for a secondary analysis may become an important source of artifacts in patient monitor data. We test an off-the-shelf integrated photoplethysmography (PPG) and electrocardiogram (ECG) monitoring device for its ability to yield a reliable pulse transit time (PTT) signal. Approach: This is a retrospective clinical study using two databases: one containing 35 subjects who underwent laparoscopic cholecystectomy, another containing 22 subjects who underwent spontaneous breathing test in the intensive care unit. All data sets include recordings of PPG and ECG using a commonly deployed patient monitor. We calculated the PTT signal offline. Main Results: We report a novel constant oscillatory pattern in the PTT signal and identify this pattern as a sawtooth artifact. We apply an approach based on the de-shape method to visualize, quantify and validate this sawtooth artifact. Significance: The PPG and ECG signals not designed for the PTT evaluation may contain unwanted artifacts. The PTT signal should be calibrated before analysis to avoid erroneous interpretation of its physiological meaning.

q-bio.QM↗

Recovery of the fetal electrocardiogram for morphological analysis from two trans-abdominal channels via optimal shrinkage

We propose a novel algorithm to recover fetal electrocardiogram (ECG) for both the fetal heart rate analysis and morphological analysis of its waveform from two or three trans-abdominal maternal ECG channels. We design an algorithm based on the optimal-shrinkage and the nonlocal Euclidean median under the wave-shape manifold model. For the fetal heart rate analysis, the algorithm is evaluated on publicly available database, 2013 PhyioNet/Computing in Cardiology Challenge, set A. For the morphological analysis, we propose to simulate semi-real databases by mixing the MIT-BIH Normal Sinus Rhythm Database and MITDB Arrhythmia Database. For the fetal R peak detection, the proposed algorithm outperforms all algorithms under comparison. For the morphological analysis, the algorithm provides an encouraging result in recovery of the fetal ECG waveform, including PR, QT and ST intervals, even when the fetus has arrhythmia. To the best of our knowledge, this is the first work focusing on recovering the fetal ECG for morphological analysis from two or three channels with an algorithm potentially applicable for continuous fetal electrocardiographic monitoring, which creates the potential for long term monitoring purpose.

eess.SP↗

Explore intrinsic geometry of sleep dynamics and predict sleep stage by unsupervised learning techniques

We propose a novel unsupervised approach for sleep dynamics exploration and automatic annotation by combining modern harmonic analysis tools. Specifically, we apply diffusion-based algorithms, diffusion map (DM) and alternating diffusion (AD) algorithms, to reconstruct the intrinsic geometry of sleep dynamics by reorganizing the spectral information of an electroencephalogram (EEG) extracted from a nonlinear-type time frequency analysis tool, the synchrosqueezing transform (SST). The visualization is achieved by the nonlinear dimension reduction properties of DM and AD. Moreover, the reconstructed nonlinear geometric structure of the sleep dynamics allows us to achieve the automatic annotation purpose. The hidden Markov model is trained to predict the sleep stage. The prediction performance is validated on a publicly available benchmark database, Physionet Sleep-EDF [extended] SC* and ST*, with the leave-one-subject-out cross validation. The overall accuracy and macro F1 achieve 82:57% and 76% in Sleep-EDF SC* and 77.01% and 71:53% in Sleep-EDF ST*, which is compatible with the state-of-the-art results by supervised learning-based algorithms. The results suggest the potential of the proposed algorithm for clinical applications.

eess.SP↗

Non-contact photoplethysmogram and instantaneous heart rate estimation from infrared face video

Extracting the instantaneous heart rate (iHR) from face videos has been well studied in recent years. It is well known that changes in skin color due to blood flow can be captured using conventional cameras. One of the main limitations of methods that rely on this principle is the need of an illumination source. Moreover, they have to be able to operate under different light conditions. One way to avoid these constraints is using infrared cameras, allowing the monitoring of iHR under low light conditions. In this work, we present a simple, principled signal extraction method that recovers the iHR from infrared face videos. We tested the procedure on 7 participants, for whom we recorded an electrocardiogram simultaneously with their infrared face video. We checked that the recovered signal matched the ground truth iHR, showing that infrared is a promising alternative to conventional video imaging for heart rate monitoring, especially in low light conditions. Code is available at https://github.com/natalialmg/IR_iHR

cs.CV↗

Connecting Dots -- from Local Covariance to Empirical Intrinsic Geometry and Locally Linear Embedding

Local covariance structure under the manifold setup has been widely applied in the machine learning society. Based on the established theoretical results, we provide an extensive study of two relevant manifold learning algorithms, empirical intrinsic geometry (EIG) and the locally linear embedding (LLE) under the manifold setup. Particularly, we show that without an accurate dimension estimation, the geodesic distance estimation by EIG might be corrupted. Furthermore, we show that by taking the local covariance matrix into account, we can more accurately estimate the local geodesic distance. When understanding LLE based on the local covariance structure, its intimate relationship with the curvature suggests a variation of LLE depending on the "truncation scheme". We provide a theoretical analysis of the variation.

math.ST↗

Diffusion-based nonlinear filtering for multimodal data fusion with application to sleep stage assessment

The problem of information fusion from multiple data-sets acquired by multimodal sensors has drawn significant research attention over the years. In this paper, we focus on a particular problem setting consisting of a physical phenomenon or a system of interest observed by multiple sensors. We assume that all sensors measure some aspects of the system of interest with additional sensor-specific and irrelevant components. Our goal is to recover the variables relevant to the observed system and to filter out the nuisance effects of the sensor-specific variables. We propose an approach based on manifold learning, which is particularly suitable for problems with multiple modalities, since it aims to capture the intrinsic structure of the data and relies on minimal prior model knowledge. Specifically, we propose a nonlinear filtering scheme, which extracts the hidden sources of variability captured by two or more sensors, that are independent of the sensor-specific components. In addition to presenting a theoretical analysis, we demonstrate our technique on real measured data for the purpose of sleep stage assessment based on multiple, multimodal sensor measurements. We show that without prior knowledge on the different modalities and on the measured system, our method gives rise to a data-driven representation that is well correlated with the underlying sleep process and is robust to noise and sensor-specific effects.

stat.ML↗

Recovering Hidden Components in Multimodal Data with Composite Diffusion Operators

Finding appropriate low dimensional representations of high-dimensional multi-modal data can be challenging, since each modality embodies unique deformations and interferences. In this paper, we address the problem using manifold learning, where the data from each modality is assumed to lie on some manifold. In this context, the goal is to characterize the relations between the different modalities by studying their underlying manifolds. We propose two new diffusion operators that allow to isolate, enhance and attenuate the hidden components of multi-modal data in a data-driven manner. Based on these new operators, efficient low-dimensional representations can be constructed for such data, which characterize the common structures and the differences between the manifolds underlying the different modalities. The capabilities of the proposed operators are demonstrated on 3D shapes and on a fetal heart rate monitoring application.

eess.SP↗