Search arXivSearch

arXiv subjects

Imran Razzak

Publications and source records attributed to Imran Razzak.

2 recordsLinked to original sources

TopoBrick: Agentic Topology Sampling of Exogenous Variables for Zero-Shot Building IoT Forecasting

Building sensors are embedded in physical topology, spatial hierarchy, and operational context, yet existing forecasters often treat them as isolated time series or rely on fixed covariate sets. We present TopoBrick, a training-free framework for zero-shot building IoT (Internet-of-Things) forecasting. TopoBrick uses building knowledge graphs to construct a compact structural skeleton and employs an agentic topology sampler to select target-specific exogenous variables. The selected variables are organized by deployment-time availability, separating past-known sensor states from future-known calendar, schedule, and meteorological exogenous variables. Across three real-world buildings, TopoBrick outperforms strong zero-shot foundation-model baselines and remains competitive with fully trained building-specific models. Ablations show that topology-aware sampling is more reliable than random, ontology-only, or fixed-hop selection, especially for physically coupled HVAC and weather-driven sensing variables.

cs.AI

MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models

Reliable evaluation of vision-language models (VLMs) and medical vision-language models (Medical-VLMs) requires calibrated confidence, particularly under realistic clinical conditions. However, existing efforts mainly focused on improving accuracy, leaving calibration in the medical domain underexplored. To this end, we propose MVC-Bench, a calibration-centric benchmark for medical image classification with VLMs and Medical-VLMs. MVC-Bench assesses the calibration across three axes: (i) robustness to modality, backbone, and domain shift (ii) effectiveness of calibration strategies and prompt-tuning methods (iii) stability under prompt-template and random-seed variations. The benchmark covers eight different backbones, three medical modalities, including fundus imaging, histopathology, and chest X-ray under in-domain and domain shift settings. It compares post-hoc calibration, train-time calibration, and zero-shot inference methods, together with six prompt-tuning methods. Across more than 1638 controlled experiments, we report accuracy and Expected Calibration Error (ECE) as primary metrics, and further report results with complementary calibration measures, including Maximum Calibration Error (MCE) and Adaptive Calibration Error (ACE). We further investigate the underlying causes of miscalibration in VLMs and Medical-VLMs and propose a simple train-time calibration method, Multi-Class Margin (MCM) regularization, which achieves lowest ECE on 10 out of 12 settings in in-domain and remains competitive under domain shifts. Collectively, MVC-Bench provides a structured evaluation framework and actionable guidance for improving calibration in safety-critical medical workflows.

cs.CV