Search arXivSearch

arXiv subjects

K. Stifter

Publications and source records attributed to K. Stifter.

8 recordsLinked to original sources

A First Demonstration of the SQUAT Detector Architecture: Direct Measurement of Resonator-Free Charge-Sensitive Transmons

The Superconducting Quasiparticle-Amplifying Transmon (SQUAT) is a new sensor architecture for THz (meV) detection based on a weakly charge-sensitive transmon directly coupled to a transmission line. In such devices, energy depositions break Cooper pairs in the qubit capacitor islands, generating quasiparticles. Quasiparticles that tunnel across the Josephson junction change the transmon qubit parity, generating a measurable signal. In this paper, we present the design of first-generation SQUATs and demonstrate an architecture validation. We summarize initial characterization measurements made with prototype devices, comment on background sources that influence the observed parity-switching rate, and present experimental results showing simultaneous detection of charge and quasiparticle signals using aluminum-based SQUATs.

physics.ins-det

SPLENDOR: a novel detector platform to search for light dark matter with narrow-gap semiconductors

We present the design and current status of SPLENDOR, a novel detector platform that combines narrow-gap semiconductor targets with low-noise charge readout to achieve sensitivity to dark matter energy deposits well below the eV scale. SPLENDOR is designed to be a modular and scalable system able to accommodate different target materials and signal readout technologies. SPLENDOR's present strategy entails: (i) the use of strongly correlated f-electron semiconductors with anisotropic electronic structures to enable not only sub-eV energy thresholds, but also directional sensitivity to the incoming dark matter flux, allowing for signal-background discrimination via daily modulation, and (ii) custom charge readout based on cryogenic high-electron-mobility transistor (cryoHEMT) amplifiers approaching single-electron resolution. We report on the selection and characterization of Eu$_5$In$_2$Sb$_6$ as the target material for SPLENDOR's first prototype detector, as well as the development and calibration of the prototype amplifier chain, achieving a measured charge resolution of 20$\pm$7 electrons in silicon test samples, consistent with predicted performance. This provides a demonstration of the detector architecture, which is now ready for deployment in a dark matter search campaign to deliver SPLENDOR's first science results. Finally, we present estimates of sensitivity reach in the parameter space of athermally produced relic dark matter under high- and low-background environments, and for various amplifier technology upgrades with increasing performance, including planned quantum sensing upgrades in order to achieve our ultimate goal of sub-electron resolution in optimized systems. SPLENDOR provides a novel approach to dark matter direct detection, combining quantum sensing with material's design to open new avenues of exploration in the sub-MeV mass range of dark matter parameter space.

physics.ins-det

Broadband Optical Modulation and Control at Millikelvin Temperatures

A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact cryogenic optical beam steering system that can be used to generate O({\mu}s) pulses of small numbers of photons over the energy range of 1.2 - 4.5eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including supercondcting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

physics.ins-det

First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility

We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$\pi$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

quant-ph

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $\mu$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

quant-ph

Estimating the Energy Threshold of Phonon-mediated Superconducting Qubit Detectors Operated in an Energy-Relaxation Sensing Scheme

In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair in most superconductors. Among them, devices based on superconducting qubits are interesting candidates for sensing due to their observed sensitivity to broken Cooper pairs. We have developed an end-to-end G4CMP-based simulation framework and have used it to evaluate performance metrics of qubit-based devices operating in a gate-based "energy relaxation" readout scheme, akin to those used in recent studies of qubit sensitivity to ionizing radiation. We find that for this readout scheme, the qubit acts as a phonon sensor with an energy threshold ranging down to $\simeq$0.4 eV for near-term performance parameters.

physics.ins-det

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.

astro-ph.CO

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

physics.ins-det