Search arXivSearch

arXiv subjects

Merlin Kole

Publications and source records attributed to Merlin Kole.

At least 19 recordsLinked to original sources

PolPy: A universal tool for X-ray/gamma-ray polarimetry using common data format standards

X-ray/gamma-ray polarimetry has been a rapidly developing field in recent years. However, the lack of standardized analysis frameworks has hindered cross-instrument comparisons and joint multi-mission studies. To address this, we present PolPy, a universal tool designed for polarimetry of high-energy astrophysical transients. Built as a plugin for the Multi-Mission Maximum Likelihood (3ML) framework, PolPy introduces standardized data and response formats, common reference frames based on IAU conventions for defining polarization angles, and a robust likelihood-based template-matching algorithm. The article briefly describes these standards and presents tests and results performed to validate the software using simulated gamma-ray burst (GRB) injections across two different mission mass models: POLAR and Daksha. Our verification tests demonstrate that PolPy accurately recovers the injected polarization angles and fractions without systematic bias. Furthermore, we show that performing simultaneous joint fits across multiple detectors and instruments can significantly improve parameter constraints compared to single-instrument analyses. By unifying data formats and methodology, PolPy enables reliable joint polarimetric analysis for current and future high-energy polarimeters.

astro-ph.IM

Design and preliminary performance study of the broad-band spectrometer detector for POLAR-2

POLAR-2, the successor of the POLAR experiment aboard China's Tiangong-2 space lab, is set to be deployed on the China Space Station. The POLAR-2 mission aims to conducting high-precision polarization measurements of high-energy transients with a primary focus on Gamma-Ray Bursts (GRBs), following POLAR's pioneering accurate polarization measurements of GRB prompt emission. One of the key advancements in POLAR-2 is the inclusion of a dedicated Broad-band Spectrometer Detector (BSD) instrument, designed to provide precise measurements of GRB location and spectral parameters, which are critical inputs for accurate polarization analysis of POLAR-2's dedicated High-energy Polarimetry Detector (HPD), which is made of plastic scintillator bars array. BSD employs a coded-aperture mask imaging technique and pixelated GAGG scintillation crystals, offering a wide half-coded field of view of ~132{\deg} x 125{\deg} and an operational energy range of 10-1000 keV. Simulation results indicate that the instrument can achieve a localization accuracy of approximately 1.5{\deg} for faint GRBs similar to GRB 170817A, satisfying the core requirements of GRB polarimetry with HPD. BSD also has moderate capability for GRB polarimetry, particularly at several hundred keV energy. This paper outlines the preliminary design of BSD and presents an overall evaluation of its expected scientific performance, based on extensive Monte Carlo simulations and preliminary ground-based calibration tests.

astro-ph.IM

Refined Constraints on the Hard X-ray Polarization of the Crab Pulsar and Nebula Derived from an Extended XL-Calibur Dataset

We present updated hard X-ray polarization measurements of the Crab pulsar and nebula obtained with the balloon-borne polarimeter XL-Calibur in the ~19-64 keV energy range. During the flight, intermittent GPS-failure resulted in poorly constrained timing for ~38% of the Crab dataset. By implementing a new phase-recovery method that reconstructs timing during extended GPS-off intervals, phase tag data is recovered for ~95% of the GPS-off dataset, increasing the precision of the phase-resolved analysis. Phase-information for the data is recovered by using the Crab pulsar, with its 33 ms period, as an external timing source. Using a Markov-Chain Monte-Carlo framework to jointly fit phase offsets and frequency derivatives, sufficient phase accuracy is achieved, across multiple periods without GPS for a phase-resolved analysis. This enables inclusion of nearly the full dataset in the polarization study. The polarization degree of the nebular emission is found to be (27.7${\pm}$4.9)% at a polarization angle of 127.2{\deg}${\pm}$5.1{\deg} confirming previous XL-Calibur results and remaining aligned with the Crab's spin axis, consistent with synchrotron emission from the inner nebula. Phase-resolved measurements show that the off-pulse and bridge intervals exhibit a strong polarization, while the pulsar peaks, although weakly constrained, remain in agreement with the softer-energy trends of IXPE. These findings reinforce a scenario in which hard X-ray emission arises primarily in the nebular torus and wind regions. The successful recovery of precise phase tagging from GPS-off data demonstrates the capacity to use the pulsar as an external clock even in the case of sparsely populated data.

astro-ph.HE

Measurements of the Birks' coefficient of GAGG:Ce using hard X-rays

Inorganic scintillators continue to be widely used within astrophysical X-ray and gamma-ray detectors. This is in part thanks to the development of new scintillators, such as GAGG:Ce, as well as the availability of new scintillator readout sensors such as Silicon Photomultipliers and Silicon Drift Detectors. In order to use such scintillator materials for spectrometry or polarimetry, a detailed understanding of their response is important. One parameter that can affect the scintillator performance, particularly at lower photon energies, is their Birks' coefficient, which correlates the relative light yield to the ionization energy density. While for many high-Z inorganic scintillators this effect can be ignored, for GAGG:Ce this appears to not be the case. Here we provide a measurement of the Birks' coefficient for GAGG:Ce using data from a detector irradiated in the 20-80~keV energy range at the LARIX-A X-ray beam in Ferrara, Italy. While the effects due to Birks' law are visible below 30 keV, they also significantly influence the performance of GAGG:Ce performance near one of the K-edges, affecting both the measured gain and the energy resolution. Here, we use beam test data to derive the Birks' coefficient from GAGG:Ce. The results indicate that for usage in hard X-ray and soft gamma-ray missions, this coefficient has a significant effect on the measurements.

astro-ph.IM

Design and Scientific Prospects of the POLAR-2 Mission

The POLAR-2 mission consists of 3 instruments designed with the combined aim of producing a deeper understanding of Gamma-Ray Bursts. To achieve this, POLAR-2 relies on polarisation measurements and, for the first time will provide these using 2 separate polarimeter detectors. The first of these is a payload optimised to perform Compton polarimetry measurements in the 40-1000 keV energy range using a combination of plastic scintillators and SiPMs. The development of this payload, the design of which is based on lessons learned from the POLAR mission, included optimization of plastic scintillator design. In addition, its development included detailed characterization, space qualification and radiation damage and mitigation strategies for the large number of silicon photo-multipliers included in the design. We will present these along with an overview of the readout electronics. These electronics were developed with flexibility in mind, as well as low cost and low power consumption. As such, its design is of interest beyond this polarimeter and is also used on the spectrometer instrument of POLAR-2 where it is used to read out an array of GAGG:Ce scintillators. This readout, in combination with a coded mask, allows this secondary instrument to provide detailed spectral and localization measurements. The final instrument used in the mission aims to use gas-based detectors to perform polarization measurements in the keV energy region. The novelty of this design is that it will be optimized to use these for wide field of view observations. The combination of the three instruments will allow to perform detailed spectral, localization and polarization measurements of these transient phenomena together for the first time. Here we provide an overview of the technologies employed in the mission along with detailed predictions on its capabilities after its launch currently foreseen in 2027.

astro-ph.IM

Gamma-Ray Burst Polarimetry with the POLAR and POLAR-2 missions

Gamma-Ray Bursts are among the most powerful and violent events in the Universe. Despite over half a century of observations of these transient sources, many open questions remain about their nature and the physical emission mechanisms at play. Polarization measurements of the GRB prompt gamma-ray emission have long been theorized to be able to answer most of these questions. Early polarization measurements did not allow to draw clear conclusions because of limited significance. With the aim of better characterizing the polarization of these prompt emissions, a compact Gamma-Ray polarimeter called POLAR has been sent to space as part of the Tiangong-2 Chinese space lab for 6 months of operations starting September 2016. The instrument detected 55 GRBs as well as several pulsars. Time-integrated polarization analysis of the 14 brightest detected GRBs has shown that the prompt emission is lowly polarized or fully unpolarized. However, time-resolved analysis depicted strong hints of an evolving polarization angle within single pulses, washing out the polarization degree in time-integrated analyses. Energy-resolved polarization analysis has shown no constraining results due to limited statistics. Hence, a more sensitive $\gamma$-ray polarimeter is required to perform detailed energy and time-resolved polarization analysis of the prompt gamma-ray emission of GRBs. Based on the success of the POLAR mission, a larger-scale instrument, approved for launch to the China Space Station (CSS) in 2027, is currently being developed by a Swiss, Chinese, Polish, and German collaboration. Thanks to its large sensitivity in the 20-800~keV range, POLAR-2 will produce polarization measurements of at least 50 GRBs per year with a precision equal to or higher than the best results published by POLAR, allowing for good quality time and energy resolved analysis.

astro-ph.HE

Low-temperature Performance of $\mathrm{Gd_3(Ga, Al)_5O_{12}}$:Ce Scintillators

The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce a significant background to the measurements, something which can be mitigated through the use of an anti-coincidence shield. For hard X-ray and gamma-ray detectors such a shield typically consists photomultiplier tubes or, more recently, silicon photomultipliers coupled to scintillators placed around the detector. When using cryogenic detectors, the shield can be placed around the entire cryostat which will make it large, heavy and expensive. For the ASCENT (A SuperConducting ENergetic x-ray Telescope) mission, which uses Transition Edge Detectors, it was therefore considered to instead place the shield inside. This comes with the challenge of operating it at cryogenic temperatures. For this purpose, we tested the performance of 2 different types of GAGG:Ce scintillators down to 15 mK for the first time. Although significant variations of both the decay time and the light yield were found when varying the temperature, at 4 K its performance was found to be similar to that at room temperature. Furthermore, unexpected behavior around 2 K was found for both types of GAGG:Ce, leading to more in depth studies around these temperatures. Overall, the studies show that the combination of materials will allow to produce a functional anti-coincidence shield at several Kelvin.

physics.ins-det

Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions

The advent of both multi-messenger and time-domain astrophysics over the last decade has seen a large interest in the development of small-scale, cheap, and robust gamma-ray detectors. This has been further encouraged by the availability of CubeSat platforms. Of particular interest are detectors capable of producing spectral and localization measurements of X and gamma-ray transients to allow for accurate follow-up measurements at different wavelengths. A vast number of the instruments developed for such purposes in the last years use a combination of scintillators and Silicon Photomultipliers (SiPMs) for photon detection. Here, we present the design, performance, and space qualification of a readout system capable of reading out 64 SiPM channels. This low-power and low-cost system was originally designed for the POLAR-2 mission, a large scale gamma-ray polarimeter. However, its flexible design makes it equally suitable for use on various CubeSat missions. The system was found to perform well when reading out both plastic and high Z scintillators using a total of 1.8~W. The space qualified design furthermore relies on commercial off-the-shelf components, thereby also removing most international export issues. In this paper, we will present the overall design, the performance of the electronics, its performance when reading out various scintillators and the successful space-qualification of this design.

astro-ph.IM

Synchrotron polarization of a hybrid distribution of relativistic thermal and nonthermal electrons in GRB prompt emission

Synchrotron polarization of relativistic nonthermal electrons in gamma-ray bursts (GRBs) has been widely studied. However, recent numerical simulations of relativistic shocks and magnetic reconnection have found that a more realistic electron distribution consists of a power-law component plus a thermal component, which requires observational validation. In this paper, we investigate synchrotron polarization using a hybrid energy distribution of relativistic thermal and nonthermal electrons within a globally toroidal magnetic field in GRB prompt emission. Our results show that, compared to the case of solely non-thermal electrons, the synchrotron polarization degrees (PDs) in these hybrid electrons can vary widely depending on different parameters and that the PD decreases progressively with frequency in the $\gamma$-ray, X-ray, and optical bands. The time-averaged PD spectrum displays a significant bump in the $\gamma$-ray and X-ray bands with the PDs higher than $\sim60\%$ if the thermal peak energy of electrons is much smaller than the conjunctive energy of electrons between the thermal and non-thermal distribution. The high synchrotron PD ($\gtrsim 60\%$) in the $\gamma$-ray and X-ray bands, which generally can not be produced by solely non-thermal electrons with typical power-law slopes, can be achieved by the hybrid electrons and primarily originates from the exponential decay part of the thermal component. Moreover, this model can roughly explain the PDs and spectral properties of some GRBs, where GRB 110301A with a high PD ($70_{-22}^{+22} \%$) may be potential evidence for the existence of relativistic thermal electrons.

astro-ph.HE

Optimizing the light output of a plastic scintillator and SiPM based detector through optical characterization and simulation: A case study for POLAR-2

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this kind of detectors are Compton polarimeters such as POLAR-2 or LEAP, for which a low-Z material is needed for the Compton effect to be dominant down to as low energy as possible. Such detectors aim to measure low energy Compton depositions which produce small amounts of optical light, and for which optimizing the instrumental optical properties consequently imperative. The light collection efficiency of such a device was studied with a focus on the POLAR-2 GRB polarimeter, in which the conversion of incoming $\gamma$-rays into readable signal goes through the production and collection of optical light, which was to be optimized both through measurements and simulations. The optical elements of the POLAR-2 polarimeter prototype module were optically characterized and an optical simulation based on Geant4 was developed to fully model its optical performances. The results from simulations were used to optimize the design and finally to verify its performance. The study resulted in a detector capable of measuring energy depositions of several keV. In addition an important finding of this work is the impact of the plastic scintillator surface roughness on the light collection. It was found that a plastic scintillator with a higher scintillation efficiency but made of a softer material, hence with a rougher surface, was not necessarily the best option to optimize the light collection. Furthermore, in order to optimize the optical crosstalk between different channels, a production technique for very thin ($\sim$150$~\mu$m) and reusable silicone-based optical coupling pads, which can be applied for other experiments, was developed.

astro-ph.IM

Response of the first POLAR-2 Prototype to Polarized Beams

POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016. POLAR-2 aims to measure the polarization of the Gamma-ray Burst prompt emission within the 30-800 keV energy range. Thanks to its high sensitivity to gamma-ray polarization, as well as its large effective area, POLAR-2 will provide the most precise measurements of this type to date. Such measurements are key to improve our understanding of the astrophysical processes responsible for Gamma-Ray Bursts. The detector consists of a segmented array of plastic scintillator bars, each one of which is read out by a Silicon PhotoMultiplier channel. The flight model of POLAR-2 will contain a total of 6400 scintillators. These are divided into 100 groups of 64 bars each, in so-called polarimeter modules. In recent years, the collaboration has designed and produced the first prototypes of these polarimeter modules and subjected these to space qualification tests. In addition, in April 2023, the first of these modules were calibrated using fully polarized gamma-ray beams at the European Synchrotron Radiation Facility (ESRF) in France. In this work, we will present the results of this calibration campaign and compare these to the simulated performance of the POLAR-2 modules. Potential improvements to the design are also discussed. Finally, the measurements are used, in combination with the verified simulation framework, to estimate the scientific performance of the full POLAR-2 detector and compare it to its predecessor.

astro-ph.IM

Future Perspectives for Gamma-ray Burst Detection from Space

Since their first discovery in the late 1960s, Gamma-ray bursts have attracted an exponentially growing interest from the international community due to their central role in the most highly debated open questions of the modern research of astronomy, astrophysics, cosmology, and fundamental physics. These range from the intimate nuclear composition of high density material within the core of ultra-dense neuron stars, to stellar evolution via the collapse of massive stars, the production and propagation of gravitational waves, as well as the exploration of the early Universe by unveiling first stars and galaxies (assessing also their evolution and cosmic re-ionization). GRBs have stimulated in the past $\sim$50 years the development of cutting-edge technological instruments for observations of high energy celestial sources from space, leading to the launch and successful operations of many different scientific missions (several of them still in data taking mode nowadays). In this review, we provide a brief description of the GRB-dedicated missions from space being designed and developed for the future. The list of these projects, not meant to be exhaustive, shall serve as a reference to interested readers to understand what is likely to come next to lead the further development of GRB research and associated phenomenology.

astro-ph.IM

HAGRID -- High Accuracy GRB Rapid Inference with Deep learning

Since their discoveries in 1967, Gamma-Ray Bursts (GRBs) continue to be one of the most researched objects in astrophysics. Multi-messenger observations are key to gaining a deeper understanding of these events. In order to facilitate such measurements, fast and accurate localization of the gamma-ray prompt emission is required. As traditional localization techniques are often time consuming or prone to significant systematic errors, here we present a novel method which can be applied on the POLAR-2 observatory. POLAR-2 is a dedicated GRB polarimeter, which will be launched towards the China Space Station (CSS) in 2025. The CSS provides POLAR-2 access to a GPU, which makes it possible and advantageous to run a Deep Learning model on it. In this work, we explore the possibility to identify GRBs in real time and to infer their location and spectra with deep learning models. Using POLAR simulations and data, a feasibility experiment was performed to implement this method on POLAR-2. Our results indicate that using this method, in combination with real time data downlinking capabilities, POLAR-2 will be able to provide accurate localization alerts within 2 minutes of the GRB onset.

astro-ph.IM

POLAR-2, the next generation of GRB polarization detector

The POLAR-2 Gamma-Ray Burst (GRB) Polarimetry mission is a follow-up to the successful POLAR mission. POLAR collected six months of data in 2016-2017 on board the Tiangong-2 Chinese Space laboratory. From a polarization study on 14 GRBs, POLAR measured an overall low polarization and a hint for an unexpected complexity in the time evolution of polarization during GRBs. Energy-dependent measurements of the GRB polarization will be presented by N. de Angelis in GA21-09 (August 2nd). These results demonstrate the need for measurements with significantly improved accuracy. Moreover, the recent discovery of gravitational waves and their connection to GRBs justifies a high-precision GRB polarimeter that can provide both high-precision polarimetry and detection of very faint GRBs. The POLAR-2 polarimeter is based on the same Compton scattering measurement principle as POLAR, but with an extended energy range and an order of magnitude increase in total effective area for polarized events. Proposed and developed by a joint effort of Switzerland, China, Poland and Germany, the device was selected for installation on the China Space Station and is scheduled to start operation for at least 2 years in 2025.

astro-ph.IM

Energy-dependent polarization of Gamma-Ray Bursts' prompt emission with the POLAR and POLAR-2 instruments

Gamma-Ray Bursts are among the most powerful events in the Universe. Despite half a century of observations of these transient sources, many open questions remain about their nature. Polarization measurements of the GRB prompt emission have long been theorized to be able to answer most of these questions. With the aim of characterizing the polarization of these prompt emissions, a compact Compton polarimeter, called POLAR, has been launched to space in September 2016. Time integrated polarization analysis of the POLAR GRB catalog have shown that the prompt emission is lowly polarized or fully unpolarized. However, time resolved analysis depicted strong hints of an evolving polarization angle within single pulses, washing out the polarization degree in time integrated analyses. Here we will for the first time present energy resolved polarization measurements with the POLAR data. The novel analysis, performed on several GRBs, will provide new insights and alter our understanding of GRB polarization. The analysis was performed using the 3ML framework to fit polarization parameters versus energy in parallel to the spectral parameters. Although limited by statistics, the results could provide a very relevant input to disentangle between existing theoretical models. In order to gather more statistics per GRB and perform joint time and energy resolved analysis, a successor instrument, called POLAR-2, is under development with a launch window early 2025 to the CSS. After presenting the first energy resolved polarization results of the POLAR mission, we will present the prospects for such measurements with the upcoming POLAR-2 mission.

astro-ph.HE

Temperature dependence of radiation damage annealing of Silicon Photomultipliers

The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space based experiments where the detectors require to be compact, lightweight and capable of surviving launch conditions. A downside with the use of this novel type of detector in space conditions is its susceptibility to radiation damage. In order to understand the lifetime of SiPMs in space, both the damage sustained due to radiation as well as the subsequent recovery, or annealing, from this damage have to be studied. Here we present these studies for three different types of SiPMs from the Hamamatsu S13360 series. Both their behaviour after sustaining radiation equivalent to 2 years in low earth orbit in a typical mission is presented, as well as the recovery of these detectors while stored in different conditions. The storage conditions varied in temperature as well as in operating voltage. The study found that the annealing depends significantly on the temperature of the detectors with those stored at high temperatures recovering significantly faster and at recovering closer to the original performance. Additionally, no significant effect from a reasonable bias voltage on the annealing was observed. Finally the annealing rate as a function of temperature is presented along with various operating strategies for the future SiPM based astrophysical detector POLAR-2 as well as for future SiPM based space borne missions.

astro-ph.IM

Adding Gamma-ray Polarimetry to the Multi-Messenger Era

The last decade has seen the emergence of two new fields within astrophysics: gamma ray polarimetry and GW astronomy. The former, which aims to measure the polarization of gamma rays in the energy range of 10s to 100s of keV, from astrophysical sources, saw the launch of the first dedicated polarimeters such as GAP and POLAR. On the other hand, GW astronomy started with the detection of the first black hole mergers by LIGO in 2015, followed by the first multi messenger detection in 2017. While the potential of the two individual fields has been discussed in detail in the literature, the potential for joint observations has thus far been ignored. In this article, we aim to define how GW observations can best contribute to gamma ray polarimetry and study the scientific potential of joint analyses. In addition we aim to provide predictions on feasibility of such joint measurements in the near future. We study which GW observables can be combined with measurements from gamma ray polarimetry to improve the discriminating power regarding GRB emission models. We then provide forecasts for the joint detection capabilities of current and future GW detectors and polarimeters. Our results show that by adding GW data to polarimetry, a single precise joint detection would allow to rule out the majority of emission models. We show that in the coming years joint detections between GW and gamma ray polarimeters might already be possible. Although these would allow to constrain part of the model space, the probability of highly constraining joint detections will remain small in the near future. However, the scientific merit held by even a single such measurement makes it important to pursue such an endeavour. Furthermore, we show that using the next generation of GW detectors, such as the Einstein Telescope, joint detections for which GW data can better complement the polarization data become possible.

astro-ph.HE

Proton Irradiation of SiPM arrays for POLAR-2

POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China. The instrument will orbit at altitudes between 340km and 450km with an inclination of 42$^{\circ}$ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-like conditions. In this paper we focus on the radiation damage of the silicon photomultiplier arrays S13361-6075NE-04 and S14161-6050HS-04 from Hamamatsu. The S13361 are irradiated with 58MeV protons at several doses up to 4.96Gy, whereas the newer series S14161 are irradiated at doses of 0.254Gy and 2.31Gy. Their respective performance degradation due to radiation damage are discussed. The equivalent exposure time in space for silicon photomultipliers inside POLAR-2 with a dose of 4.96Gy is 62.9 years (or 1.78 years when disregarding the shielding from the instrument). Primary characteristics of the I-V curves are an increase in the dark current and dark counts, mostly through cross-talk events. Annealing processes at $25^{\circ}C$ were observed but not studied in further detail. Biasing channels while being irradiated have not resulted in any significant impact. Activation analyses showed a dominant contribution of $\beta^{+}$ particles around 511keV. These resulted primarily from copper and carbon, mostly with decay times shorter than the orbital period.

astro-ph.IM