Single-electron detection in a high-purity Ge device

High-purity germanium (HPGe) detectors are among the most powerful instruments for gamma ray spectroscopy, combining exceptional energy resolution with large active volumes. Although they operate close to the fundamental resolution limit at high energies, their performance at very low energies has long been limited by electronic noise, restricting detection thresholds to above approximately 30 electron-hole pairs ($\sim$100 eV). Here we introduce a cryogenic HPGe detector architecture that achieves single electron-hole pair sensitivity by calorimetrically measuring ionization at temperatures near 20 mK. The device integrates a NbSi transition-edge sensor into a point-contact-inspired geometry, concentrating athermal phonon energy generated during charge drift and enabling eV-scale sensitivity ultimately set by the semiconductor band gap. Beyond single-charge detection, the device rejects the low-energy excess background that limits existing cryogenic low-threshold technologies, establishing a pathway towards discrimination between electron- and nuclear-recoil events below 100 eV. These advances open a route towards next-generation detectors for direct dark matter searches, coherent elastic neutrino-nucleus scattering, and nuclear reactor monitoring for non-proliferation applications.

physics.ins-det

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det