Search arXiv⌕ Search

arXiv subjects

Xiaofeng Yang

Publications and source records attributed to Xiaofeng Yang.

At least 19 recordsLinked to original sources

GRAC: Graph-Based Retrieval-Augmented Captioning for Surgical Scene Description

Purpose: Surgical operative reports support procedural documentation, surgical training, performance assessment, and workflow review. However, extracting meaningful information often requires extensive manual review and clinical expertise. Automated surgical scene descriptions could reduce this burden by leveraging recurring surgical activities and prior knowledge. Methods: We propose GRAC (Graph-Based Retrieval-Augmented Captioning), a framework that represents surgical scenes as graphs capturing relationships among instruments, actions, and anatomical structures. Given an input scene graph, GRAC learns to retrieve relevant graph-caption pairs from training data. It compares instrument-tissue interactions between retrieved examples and the input scene, using comparison features to condition retrieved-caption representations during generation. Results: On the EndoVis-18 benchmark, GRAC achieved a CIDEr-D of 5.88, compared with 4.23 for SGT and 3.36 for the strongest conventional Transformer baseline. Exact instrument-action-target triplet-set accuracy reached 52.6%, compared with 32.7% for SGT and 26.2% for the strongest conventional baseline. These results demonstrate improvements in language quality and factual agreement. On TORS, GRAC achieved a CIDEr-D of 5.06, compared with 3.80 for the strongest baseline. Conclusion: GRAC demonstrates that combining structured surgical scene representations with retrieved examples improves surgical scene captioning and produces more contextually meaningful descriptions.

cs.CV↗

GroundSeek-CXR: Retrospective Evaluation-Guided Active Observation Framework for Multi-Label Chest Radiography Diagnosis

Chest radiography (CXR) diagnosis is critical for thoracic disease assessment, yet challenged by the need to identify subtle lesions and co-occurring abnormalities across regions. While recent vision-language models can actively observe local regions, existing preference-based methods supervise each observation by its immediate effect on the current diagnosis, failing to capture how each observation and stopping decision contributes to the final diagnosis. To address this issue, we propose GroundSeek-CXR, an active CXR diagnosis framework that learns observation and stopping decisions by retrospectively evaluating them with the final diagnosis. Specifically, we first devise a Retrospective Diagnostic Evaluation (RDE) that scores observation and stop candidates from offline Monte Carlo tree search through independent continuations. Moreover, we design a Retrospective Gap-weighted Preference Optimization (RGPO) that learns from retrospective-score preferences weighted by their score gaps, prioritizing actions that improve diagnostic accuracy. Extensive experiments demonstrate that our GroundSeek-CXR framework outperforms state-of-the-art methods, and improves abnormal-image sample-F1 by 4.48% over immediate-score preference learning.

cs.CV↗

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

cs.CV↗

Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

Background: Limited tumor annotations and incomplete labels across MRI datasets hinder unified segmentation of pancreatic tumors and organs at risk (OARs) for MRI-guided radiotherapy. Purpose: We propose Pancreas-MedNeXt, a unified model that segments the whole pancreas, its subregions, tumors, and surrounding OARs from one MRI volume. Methods: The model uses a shared MedNeXt encoder-decoder with supervised whole-pancreas and subregion pretraining, followed by multitask fine-tuning. Three output heads predict the pancreatic subregions, tumor, and OARs (stomach, duodenum, kidneys). An annotation-aware loss allows training on partially labeled data without treating unannotated structures as background. Pancreas and tumor were evaluated by three-fold cross-validation on 142 PANTHER patients (92 diagnostic, 50 MR-Linac), subregions and OARs on Cyst-X and AMOS test sets, and pancreas and OARs on 33 external T1-weighted TotalSegmentator scans. Comparisons with nnU-Net, MedNeXt, VISTA3D, and Swin UNETR used the Dice similarity coefficient (DSC) with paired bootstrap 95% CIs. Results: Pancreas-MedNeXt achieved the highest mean pancreas and tumor DSC on diagnostic and MR-Linac MRI. Tumor DSC was 58.41% and 42.55%, exceeding task-specific MedNeXt by 4.94 (95% CI: 0.28-9.45) and 5.89 (95% CI: 2.37-9.72) percentage points, respectively. Whole-pancreas DSC was 85.73% and 70.66%. Pretraining improved head, body, and tail DSC by 2.01, 3.00, and 3.78 percentage points over training from scratch. It also achieved the highest DSC for the pancreas, duodenum, and right kidney on AMOS, and for all five organs on external MRI, exceeding the next-best method by 4.92-8.85 percentage points.Conclusion: A single Pancreas-MedNeXt model segments tumors, pancreatic subregions, and OARs on diagnostic and MR-Linac MRI, which could streamline contouring for pancreatic cancer radiotherapy.

cs.CV↗

Theoretical Consistency and Observational Constraints on Entropic Cosmology

Recent DESI DR2 results suggest that dark energy may evolve with time, which motivates a re-examination of entropic cosmology. In this work, we study three representative entropic models, denoted as Models A, B, and C, corresponding to the driving terms $H^2$, $H^2+\dot H$, and $H^2+\dot H+H^4$, respectively. We establish a general framework for entropic cosmology and examine these models through early universe consistency, the Trans-Planckian Censorship Conjecture (TCC), and the realization of Quintom-B crossing. We constrain these models using the Pantheon+ sample, DESI DR2 BAO measurements, and Planck 2018 CMB distance priors, and compare their fits to the data. For Model C, we adopt a first-order perturbative treatment in the full data analysis to maintain numerical stability in the presence of the higher-order term. We find that Model A is the simplest among the three models, but it is difficult to make it compatible with both early universe consistency and the TCC condition. Model B, which includes a derivative correction term, shows a small difference in the fit to observational data compared to Model A, and is more consistent with the theoretical constraints. Model C includes more correction terms, but does not provide a better fit to the data. The parameter region favored by observations does not fully overlap with that preferred by theoretical consistency, which suggests that entropic cosmology may require further development to achieve a self-consistent description across different cosmic epochs.

astro-ph.CO↗

Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge

Background: Metal implants cause streaking and shading artifacts in computed tomography (CT), obscuring anatomy and distorting Hounsfield-unit (HU) values. Conventional diffusion models reconstruct images from Gaussian noise rather than directly exploiting anatomical information retained in artifact-corrupted CT. Purpose: To develop an image-domain metal artifact reduction (MAR) method connecting artifact-corrupted and metal-free CT images through an endpoint-conditioned diffusion bridge. Methods: The proposed RDBM-MAR method uses an endpoint-conditioned diffusion bridge and initializes reconstruction from the artifact CT image. A conditional U-Net predicts an image-domain correction from intermediate bridge states. Inference uses 10 deterministic reverse steps. We used 14,000 paired CT slices from the AAPM CT-MAR Grand Challenge, including 12,045 training, 633 validation, and 1,322 held-out test slices. One clinical benchmark case was assessed qualitatively. We compared RDBM-MAR with CycleGAN, Pix2Pix, Res-SRDiff, I2I-Mamba, and I2SB using PSNR, SSIM, MAE, and LPIPS. Statistical analysis used Friedman and paired Wilcoxon signed-rank tests with Holm correction. Results: RDBM-MAR achieved the highest PSNR (43.67 +/- 4.56 dB) and SSIM (0.9856 +/- 0.0138) and the lowest MAE (14.74 +/- 8.68 HU). All four metrics differed significantly among methods (p < 0.001). RDBM-MAR outperformed all five comparators in PSNR, SSIM, and MAE (adjusted p < 0.001); Res-SRDiff achieved the lowest LPIPS. Difference maps, HU profiles, and the clinical case showed reduced artifacts with preservation of surrounding anatomy. Conclusions: RDBM-MAR provides a direct restoration trajectory from artifact CT toward metal-free CT, achieving strong structural fidelity and HU accuracy using 10 reverse steps.

physics.med-ph↗

Foundation Models in Medical Image Analysis: A Systematic Review and Meta-Analysis

Recent advancements in foundation models (FMs) have catalyzed a paradigm shift in medical image analysis. Unlike traditional task-specific artificial intelligence (AI) models, FMs leverage large-scale datasets to learn generalized representations that can be adapted to downstream clinical applications. Despite the rapid proliferation of FM research in medical imaging, there is a lack of unified synthesis that systematically maps the evolution of architectures, training paradigms, and clinical applications across modalities. To address this gap, this review provides a comprehensive and structured synthesis of FMs in medical image analysis by systematically organizing studies into two primary categories: vision-only foundation models (VFMs) and vision-language foundation models (VLFMs), based on their architectural foundations, training strategies, and downstream clinical tasks. A quantitative analysis was conducted on both VFMs and VLFMs to characterize temporal trends in dataset utilization and application domains, along with pooled performance and subgroup analyses. We also critically discuss persistent challenges, including cross-domain generalization, computational scalability, FM evaluation, fairness, and deployment. Finally, we identify key future research directions aimed at enhancing the robustness, interpretability, and clinical integration of FMs, thereby accelerating their translation into real-world medical practice.

cs.CV↗

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

cs.CV↗

CLASHarness: Benchmarking Multi-Agent Conflict in Computer Use via a Controllable and Verifiable Generation Pipeline

Vision-language models (VLMs) are increasingly deployed in multi-agent systems to automate complex computer-use workflows, yet existing benchmarks mostly assume consistent, cooperative environments. In contrast, real-world collaboration rarely runs on consistent information: peer or sub-agents frequently report outdated states, issue contradictory instructions, or compete over shared permissions and files, forcing agents to check others' outputs and verify ground truth in the environment. Evaluating such conflict resolution remains challenging: manual authoring cannot scale across complex systems, while unconstrained LLM generation produces narrative drift, answer leakage, and unsatisfiable rubrics. We introduce CLASHarness (Conflict-Loaded Agent Scenario Harness), a controllable framework for generating verifiable multi-agent conflicts in computer use, with a benchmark of 600 multi-round tasks. By combining hierarchical scenario planning with an eight-step verified micro-pipeline, CLASHarness pre-commits decisive visual facts before rendering and compiles hybrid code and semantic graders directly from executed reference trajectories, guaranteeing every task is solvable by construction. Evaluating 15 frontier models on CLASHarness reveals three core bottlenecks. First, when sub-agent outputs conflict with the environment, weaker models blindly follow misleading information, whereas stronger models inspect visual evidence to verify ground truth. Second, resolving conflicts is much harder than finding them: while agents can spot inconsistencies, actively fixing system state drops task success significantly. Third, coordination protocols remain a universal bottleneck: even frontier models fail over 58% of closing actions, often forgetting to release shared locks or hand off tasks. CLASHarness provides a scalable, verifiable foundation for building reliable multi-agent systems.

cs.MA↗

Interacting dark energy constraints from Fermi GRBs and Pantheon+ SNe Ia with full GRB covariance

The standard $Λ$CDM model faces long-standing theoretical and observational problems, such as the Hubble tension, which motivate extensions beyond $Λ$CDM, including interacting dark energy (IDE). Type Ia supernovae (SNe Ia) are precise probes of the late-time expansion history, while gamma-ray bursts (GRBs) can extend the Hubble diagram to higher redshifts. However, GRB cosmology depends on careful calibration and uncertainty modeling. Using an Amati relation calibrated with the corresponding low-redshift GRBs, we construct distance moduli for the high-redshift subsets of the 15-year \textit{Fermi}/GBM GOLD and FULL samples and combine them with Pantheon+ SNe Ia to compare flat $Λ$CDM, $w$CDM, IDE-$ρ_{\rm de}$, and IDE-$ρ_{\rm c}$ models. The covariance of the calibrated Amati intercept and slope is propagated into a full, non-diagonal GRB distance-modulus covariance, and an effective residual scatter, $σ_{\rm res,μ}$, is fitted jointly with the cosmological parameters. The GOLD and FULL samples yield very similar constraints on the main cosmological parameters. With either the full or diagonal GRB covariance, the IDE models do not improve likelihood sufficiently to compensate for their additional parameters, and the BIC favors $Λ$CDM. A SNe-only comparison shows that the additional constraining power of the GRBs is generally modest. Current GRB and Pantheon+ distance measurements provide no significant evidence for either of the two IDE interactions considered here.

astro-ph.CO↗

EditVerse3D: High-Quality 3D Object Editing with Region-Aware Learning

Local editing of 3D objects remains a long-standing challenge. When interacting with 3D content, humans naturally tend to specify a coarse region of interest for modification rather than defining precise editing boundaries. However, previous methods rely on fully edited 2D images, precise 3D masks, or redundant pipelines, which present a gap. To bridge this gap, we propose EditVerse3D, a novel 3D editing framework that enables high-quality object editing under such coarse guidance. Our approach takes as input a 3D object to be edited, a coarse 3D bounding box indicating the target region, and a reference 2D image describing the desired modification. It produces a coherent, high-fidelity edited 3D object. To facilitate this editing, we introduce a novel region-aware adaptive loss that emphasizes hard-to-learn regions and balances the objective between target and preserved areas. Complementing our loss function, we enhance model robustness and generalization through targeted data augmentations, such as training with scaled 3D masks and filtering out unrealistic editing pairs. We construct a large-scale 3D editing dataset derived from parts information. Extensive experiments demonstrate that EditVerse3D achieves superior visual quality and quantitative performance compared to existing 3D editing approaches. Please visit our project page at https://editverse3d.github.io.

cs.CV↗

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.

physics.med-ph↗

Artificial Intelligence Across the Cardiac Amyloidosis Diagnostic and Management Pathway: From Single-Modality Detection to Multimodal Clinical Integration

Cardiac amyloidosis (CA) is increasingly recognized but remains substantially underdiagnosed because its clinical and imaging phenotype overlaps with more common cardiomyopathies. Definitive subtype assignment and management further require integration of multimodal evidence to distinguish transthyretin from light-chain disease. Machine learning and deep learning have been applied across the diagnostic and management pathway. These applications span electrocardiography (ECG), echocardiography, and health record-based case finding, as well as cardiac magnetic resonance (CMR) and nuclear interpretation, including single-photon emission computed tomography/computed tomography (SPECT/CT) biomarker quantification, prognostic modeling, and treatment response assessment. This narrative review synthesizes these studies by clinical tasks, namely screening, detection, quantification, prognosis, and longitudinal assessment after treatment initiation, rather than by input modality. This task-based organization clarifies why apparently similar AI models require different cohorts, reference standards, evaluation metrics, and implementation thresholds. The evidence reveals a maturity gradient. Binary detection and AI-assisted interpretation of cardiac scintigraphy with bone-avid tracers and SPECT/CT currently represent one of the more mature AI applications in cardiac amyloidosis, supporting standardized image interpretation and quantitative biomarker extraction. However, patient-level diagnosis still requires integration with monoclonal protein testing, SPECT/CT localization, clinical context, and biopsy or tissue typing when indicated.

physics.med-ph↗

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.

physics.med-ph↗

A radiographic world model for clinical reasoning and evidence generation

Medical imaging artificial intelligence (AI) is commonly developed as separate mappings from radiographs to diagnostic outputs or from clinical descriptions to generated images, although both arise from the same underlying radiographic state. A world-model formulation instead seeks to learn an internal representation of this state that can support both clinical readout and conditional simulation of radiographic observations. Here we introduce MedDream, a radiographic world model that learns a shared continuous latent state from paired chest radiograph-text observations for diagnostic reasoning and report-conditioned evidence generation. MedDream was pretrained on 2.65 million leakage-controlled chest radiograph-text pairs curated from 4.40 million candidates. Across eight clinical datasets and two independent reader cohorts, MedDream outperformed leading diagnostic and generative comparators. For diagnostic reasoning, MedDream showed strong generalization across disease recognition, label-scarce adaptation, severity assessment, and localization, while MedDream-supported review increased mean resident concordance with independent radiologist consensus from 56.3% to 63.0%. For evidence generation, MedDream produced radiographs that preserved clinically relevant pathology and improved downstream performance on held-out real data, with synthetic augmentation increasing external VinDr-CXR macro-AUROC from 76.4% to 81.4%. More importantly, conditioning generation on prespecified subgroup performance gaps enabled targeted evidence construction, increasing weighted F1 by 3.1 percentage points in Asian patients, whereas matched-volume unguided augmentation decreased it by 2.3 points. These findings establish radiographic world models as a path toward medical AI that learns clinically meaningful internal states for interpreting, simulating, and constructing evidence for clinical use.

cs.AI↗

Studies on the dark sector interaction from joint analysis of cosmological probes

We test whether constraints on the nonlinear interaction $ξ$IDE are stable under different treatments of the Type Ia supernovae absolute calibration. \textit{Fermi} GRBs measurements and the Amati-relation parameters are fitted jointly with PantheonPlus SNe Ia, DESI DR2 BAO, and an updated cosmic-chronometer compilation. We compare the PantheonPlus-SH0ES route, which retains the SN absolute calibration, with the PantheonPlus-only route, in which the SN absolute magnitude is analytically marginalized. The GOLD GRB sample is adopted for the main analysis, while the FULL GRB sample is used to assess sample dependence. For the interaction parameter $γ\equivξ+3w$, where $γ=0$ denotes the non-interacting limit, the GOLD sample gives $γ=1.453^{+1.297}_{-1.597}$ for the PantheonPlus-SH0ES and $γ=-0.634^{+1.668}_{-2.486}$ for the PantheonPlus-only. Although the posterior medians correspond to opposite directions of energy transfer, neither route excludes $γ=0$ at 68\% credibility, and the reconstructed interaction rate remains consistent with zero over the redshift range considered. Replacing the GOLD sample with the FULL sample produces negligible changes in the interaction constraints. Moreover, $w$CDM and CPL achieve likelihood improvements comparable to that of $ξ$IDE, while the information criteria do not consistently favor the interacting model. A redshift-bin diagnostic finds no significant redshift evolution of the Amati relation. We find no compelling evidence for a dark sector interaction that is robust to the choice of SN calibration or specifically favored over noninteracting dark energy extensions.

astro-ph.CO↗

Measurement of the Weyl Potential Evolution and $E_G$ Statistic from KiDS-1000, BOSS and 2dFLenS

A recently developed model-independent approach to measuring the Weyl potential has shown some tensions with $Λ$CDM (Lambda Cold Dark Matter) in DES (Dark Energy Survey) Y3 data. We apply this framework to Kilo-Degree Survey (KiDS-1000) weak lensing and BOSS/2dFLenS galaxy clustering using the KiDS Cosmology Analysis Pipeline (KCAP) in two redshift bins. To apply this method to the BOSS spectroscopic wedges, we take the early-time power spectrum from a redshift where General Relativity (GR) is recovered and jointly fit the late-time observables $\hat{b}$, $\hat{f}$, and $\hat{J}$. With Planck18 priors, the CMASS measurement of $\hat{J}$ is $1.50σ$ below the GR prediction, while the LOWZ measurement remains consistent with it. The decrease in the central value of $\hat{J}$ from LOWZ to CMASS provides a mild indication of the previously reported ``Lensing is low'' behavior. Without Planck18 priors, we obtain $E_G(0.38)=0.503\pm0.054$ and $E_G(0.61)=0.444\pm0.054$, both consistent with GR. Furthermore, phenomenological gravity tests also show no significant preference for modified gravity.

astro-ph.CO↗

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

cs.CV↗