Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen, Tung-Ho Wu, Ping-Hsiu Wu, Justin Roper, Jun Zhou, Minglei Kang, Bill Stokes, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang. 2026-09-30. An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study. https://arxiv.org/abs/2609.39010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Toward opportunistic coronary artery calcium assessment from dual-layer dual-energy chest radiography using deep learning: a simulation study

Background: Coronary artery calcium (CAC) predicts cardiovascular risk. Dual-energy (DE) chest radiography may enable accessible opportunistic CAC assessment by separating calcifications from overlapping bone. Purpose: To evaluate multi-task deep learning for CAC localization and CT-referenced score prediction and assess projection, image representation, and exposure effects. Methods: This retrospective simulation study used 550 calcium-scoring CT exams with reference CAC masks and Agatston scores. Dual-layer DE radiographs were simulated with a physics-based detector model. A modified nnU-Net jointly predicted CAC localization and scores from continuous probability maps. Comparisons included AP, 45°, and lateral views; lateral single-energy (SE), DE bone, and high-pass filtered DE bone images; and dose-matched models at 70, 50, and 24 mAs. Patient-level splitting reserved 10% for independent testing; five-fold models provided averaged inference. Metrics included Dice and AUC at CAC thresholds >0, >100, >400, and >1000, with bootstrap uncertainty and paired DeLong tests with Holm-Bonferroni correction. Results: Lateral views achieved Dice 0.34 versus 0.23 (AP) and 0.22 (45°), with AUCs for CAC >100 of 0.86, 0.81, and 0.77, respectively; AUC differences were not significant after correction. Lateral DE bone outperformed SE (Dice: 0.33 vs. 0.19; AUC for CAC >100: 0.86 vs. 0.64), with significant AUC advantages at >100, >400, and >1000. High-pass filtering added little classification benefit. Dice decreased with exposure, while AUC differences across doses were not significant. Conclusions: Simulation results support lateral dual-layer DE bone imaging for opportunistic CAC assessment, with significant advantages over SE. Physical and clinical validation is needed.

physics.med-ph↗

Quantitative Imaging of Scandium Isotopes with a Long Axial Field-of-View PET/CT

Objective. $^{43}$Sc and $^{44}$Sc are positron-emitting isotopes of scandium that have attracted growing interest for theranostic applications in conjunction with the therapeutic isotope $^{47}$Sc. Both isotopes are non-pure positron emitters, and the associated prompt-gamma emission together with the high positron energy introduce complexities in achieving precise quantitative imaging. Approach. We evaluated the quantitative imaging performance of $^{44}$Sc and a $^{43/44}$Sc mixture on a long axial field-of-view (LAFOV) PET/CT using a NEMA IEC body phantom. We assessed contrast recovery coefficients, image noise and bias for different numbers of iterations and for absolute versus relative scatter correction, and implemented an isotope-specific point-spread-function (PSF) correction based on FLUKA-simulated positron ranges. Main results. The quantitative imaging performance of both isotopes is comparable to $^{18}$F, and the vendor's prompt-gamma correction effectively suppresses the additional random coincidences and lung error caused by prompt-gamma emission. The isotope-specific PSF correction further improves contrast recovery. While the bias obtained for $^{44}$Sc meets the EARL acceptance criterion for non-standard radionuclides, the bias for the $^{43/44}$Sc mixture exceeds it, which we attribute to the mixture-specific cross-calibration of the dose calibrators rather than to the PET imaging. Significance. Our results support the use of LAFOV PET/CT for quantitative imaging of scandium isotopes and provide practical reconstruction recommendations for clinical protocols.

physics.med-ph↗

Three-dimensional stochastic retinal models for synthetic eye-models

Purpose: Current eye models often assume a fixed spherical retinal curvature of 12 mm, which does not reflect the anatomical variability observed in vivo. This study proposes an extension incorporating the stochastic relationship between axial length and three-dimensional (3D) retinal curvature, enabling more realistic 3D eye models. Methods: Axial length and 3D retinal curvature data from 94 subjects, split into five subsets for cross-validation, were used to construct two probabilistic models: a Single Gaussian Model (SGM) and two-component Multi Gaussian Mixture Model (MGMM). Both were converted into conditional forms to estimate retinal curvature for a specific axial length, and evaluated against measured data distributions. Results: All models produced radii of curvature comparable to measured data (median difference <0.2 mm). Non-conditionally, the MGMM described the distribution slightly better than SGM, with higher density overlap (>94% vs. >86%), but similar variance (worst f-test (p-value) 1.05 (0.71) vs. 1.05 (0.73)). Conditioned on axial length, both models performed similarly with overlap exceeding 93% and the worst f-test 1.02 (0.84). Given its simplicity and robustness, the conditional SGM was selected, achieving similar validation results: median difference (<0.10 mm), overlap (>92%), and a non-significant worst f-test (1.02 (0.85)). Conclusions: The conditional SGM enables accurate generation of anatomically realistic 3D retinal curvatures based on axial length, supporting improved stochastic eye modeling for visual optics and population-based simulations of healthy eyes. Translational relevance: Replacing the fixed 12 mm retina assumption with a population-based stochastic model improves anatomical accuracy of eye models used in optical design and treatment planning.

physics.med-ph↗